The Packing Set is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It's purpose is to create a seal and keep solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope, graphite bushing and new PEEK bushing.
For the A200/A200i instruments, refer to document 04-Packing and Agitator Replacement (A200/A200i) shown below.
For the DELTA and A2000 instruments, refer to document 02-Packing and Agitator Replacement shown below.
The Agitator with packing Set is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. This is used to replace a worn or pitted agitator and with the packng set creates a seal to keep soution from leaking from the vessel into the interior cabinet. This includes the agitator, two lengths of graphite rope, graphite bushing and PEEK bushing.
For the A200/A200i instruments, refer to document 04-Packing and Agitator Replacement (A200/A200i) shown below.
For the DELTA and A2000 instruments, refer to document 02-Packing and Agitator Replacement shown below.
The Brass Packing Nut is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber Instruments. When properly tightened this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet.
For the A200/A200i instruments, refer to document 04-Packing and Agitator Replacement (A200/A200i) shown below.
For the DELTA and A2000 instruments, refer to document 02-Packing and Agitator Replacement shown below.
The Drip Tray is part of the Maintenance Alert Assembly and is used in the DELTA, A200 and A2000 instruments. It functions as a collector for a fluid leak around the agitator, diverting it away from the motor.
The Agitator Apron is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
The Bag Suspender w/weight is used within the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
This is a replacement upper tray for the bag suspender which is found in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
The Kynar Tip and Washer assembly is used when the Kynar tip has bcome worn. It is located at the bottom of the bag suspender used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. A worn tip can inhibit proper agitation and should be replaced whenever significant wear is observed.
The Bag Suspender Rod w/Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments.
The Bag Weight, machined is used on the top of the bag suspender within the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It is necessary to hold the trays in place, which in turn hold the filter bags in suspension, during the digestion process and agitation.
The Helical Coupler is used on the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel.
For the A200/A200i instruments, refer to document 04-Packing and Agitator Replacement (A200/A200i) shown below.
For the DELTA and A2000 instruments, refer to document 02-Packing and Agitator Replacement shown below.
The ETS Snap Disc Thermostat is used in the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
The replacement Hose Coupler is used on the DELTA, DELTAI, A200, A200I, A2000 & A2000I Fiber instruments. It connects to the drain hose at the side of the instrument.
This water heater, 120v can be used with the DELTA, DELTAI, A2000 or A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage Transformer (part # 6227), sold separately.
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
This sample is to be used with the ANKOM DELTA, DELTAI, A200, A200I, A2000, and A2000I Fiber Analyzers. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, contact ANKOM Technology at www.ankom.com/contact/analytical-services or call 1-315-986-8090.
The Hinge Block Assembly is found in the A200/A200I Fiber Instruments. The assembly includes a shoulder bolt and is used to secured the lid to the vessel during sample digestion.
The Lid & Hinge Block Assembly is found in the A200/A200I Fiber Instruments. Together these seal the vessel during sample digestion. It includes both the lid and the hinge block that secures the lid closed, as well as two replacement shoulder bolts.