The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application:
1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before and after a fat extraction using an ANKOMXT15 or ANKOMXT10 Extractor.
2) The RD2 Dryer Neutralizing Filter is used when drying filter bags after a hydrolysis operation is done with an ANKOMHCl Hydrolysis System.
When purchasing an RD Dryer, please select the filter that is best for your application. Additional filters can be purchased separately.
The ANKOM RD Dryer 220v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application:
1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before and after a fat extraction using an ANKOMXT15 or ANKOMXT10 Extractor.
2) The RD2 Dryer Neutralizing Filter is used when drying filter bags after a hydrolysis operation is done with an ANKOMHCl Hydrolysis System.
When purchasing an RD Dryer, please select the filter that is best for your application. Additional filters can be purchased separately.
Located on the top of the dryer, this filter is used when drying filter bags before and after a fat extraction done with an ANKOMXT10 or an ANKOMXT15 Extractor.
The 101.2 Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample.
This part is especially useful during the weighing process.
This sample is to be used with our HCL instrument. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, please contact ANKOM Technology at [email protected]
Ideally you want to remove as much acid as possible from samples before drying them.
When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCL extraction, and before drying in the dryer.
The HCL Extraction Chamber must be sealed during an assay.
The H3 lid seals the Extraction Chamber in the HCL instrument.
This assembly does not include the latch that secures the lid to the instrument.
The HCL Extraction Chamber must be sealed during an assay.
The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCL instrument.
This assembly includes the latch that secures the lid to the instrument.
This part goes inside the Solenoid Supply Valves on the XT10, XT15, HCl, DELTA & TDF instruments and is inserted onto the end of the Valve Plunger. Note: XT10 & XT15 - This part seals the water valve to prevent leaking or back flow. For details on replacing this part refer to the following Service Procedures:
This spring goes inside the Solenoid Supply Valves on the XT10, XT15, HCl, DELTA & TDF instruments and is inserted inside the Valve Plunger. Note: XT10 & XT15 - This spring cannot be used in valve Q5. For replacing the Q5 Valve Spring, contact [email protected]. For details on replacing this part refer to the following Service Procedures:
This Viton O-ring is used within the Solenoid Supply Valves on the XT10, XT15, HCl, DELTA & TDF instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide tube. For details on replacing this part refer to the following Service Procedures: