The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10, XT10I, XT15,XT15I, HCL, HCLI, DELTA, DELTAI, A2000, A2000I, TDF & TDFI instruments.
This Viton™ O-ring is used within the solenoid supply valves on the XT10, XT10I, XT15, XT15I, HCL, HCLI, DELTA, DELTAI, A2000, A2000I, TDF & TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide tube.
The Valve Spring is used inside the solenoid supply valves on the XT10, XT10I, XT15, XT15I, HCL, HCLI, DELTA, DELTAI, A2000, A2000I, TDF & TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10, XT10I, XT15 & XT15I - This spring cannot be used in valve Q5. For replacing the Q5 Valve Spring, order part X35.
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10, XT10I, XT15, XT15I, HCL, HCLI, DELTA, DELTAI, A2000, A2000I, TDF & TDFI instruments and is used to replace a damaged, worn or corroded component.
DELTA: found in the DELTA13 Vent Valve Assembly and DELTA?? Water Valve Assembly.
A2000: found in the A21 Water valve Assembly (Q6) and A22 Vent Valve Assembly (Q7).
XT10: found in the X62 Solvent Drain Valve Assembly (Q1, Q2, Q3) and X63 Water Valve Assembly (Q5, Q6).
XT15: found in the X61 Vent valve Assembly (Q7), X62 Solvent Drain Valve Assembly (Q1, Q2, Q3), X63 Water Valve Assembly (Q5, Q6), and X66 Fill Valve Assembly (Q4).
HCL: found in the H4 HCL Water Supply Valve Assembly (Q2).
TDF: found in the TDF25 Supply Valve Assembly (Water, Buffer, EtOH78, EtOH95).
A 5605 Clear Glass Bottle with protective coating is one of the bottle options that can be used with an RF1 Gas Production Module or used to collect solvent vented from the XT15 and XT10 Instruments.
This bottle provides the following features:
- up to 500ml of space to hold material
- a protective coating to protect against breakage
The LCD Screen Assembly is used in the XT10, XT15 & HCL Fat extractors and DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time and other functions during an extraction or digestion.
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10, XT10I, XT15, XT15I, HCL, HCLI, RD, RDI, TDF, TDFI, D200, D200I, DELTA, DELTAI, A200, A200I, A2000, A2000I, FLEX & FLEXI. On the D200/D200I Daisy Incubator this switch also functions as the Heat and Rotate on/off switch.
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
This Fat sample is to be used with our XT15/XT10/HCl instruments. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, please contact ANKOM Technology at www.ankom.com/contact/analytical-services.
This 10amp fuse is used in 120v AC input to the HCl, XT10 and XT15 and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
The TCH1 Julabo Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Julabo Chiller can support up to two extractors at the same time.
• 0° to 40°C process temperatures.
• ±0.5°C temperature stability.
Click the link below to see the Chiller information sheet.
The TCH2 Julabo Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Julabo Chiller can support up to two extractors at the same time.
• 0° to 40°C process temperatures.
• ±0.5°C temperature stability.
Use TCH3 if you need a 230v/60Hz product.
Click the link below to see the Chiller information sheet
The TCH3 Julabo Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH3 chiller can be used with either the XT10 or XT15 extractors. One Julabo Chiller can support up to two extractors at the same time.
• 0° to 40°C process temperatures.
• ±0.5°C temperature stability.
Click the link below to see the Chiller information sheet
This O-Ring Kit includes an Extraction Vessel seal (part # 969.5) and a Cup Insert Top seal (part # 5806). Use this kit when running Pet Ether in your instrument.
This kit is no longer available. However, the components of the X87 kit can be ordered individually as parts 969.5 and 5806.
This gauge shows the amount of pressure within the Extraction Vessel during instrument operation. Operating pressure will vary depending on the solvent being used.
Wire brush for cleaning the bottom of the XT10/XT10I and XT15/XT15I vessel. If fat residues burn to the bottom of the vessel this tool when used with a drill will assist with cleaning.
The X78 Flow Control Assembly is used to visually indicate that water is flowing through the reflux circuit during the reflux cycle. Once the solvent has reached extraction temperature, the reflux circuit will cycle on and off. When on, a red light on the control panel will illuminate, the reflux water valve will turn on, and a float in the Flow Control Assembly will rise to a level between 2-7 (we recommend a level of 4 or more if you are using a chiller water supply of 15C or less, or a level of 5 or more if you are using a lab water supply of 23C or less). When the reflux circuit is on, the control knob can be used to adjust the flow, but it is factory set and not normally adjusted.
The XT Solvent Drain Valve Assembly is used in the XT15/XT15i and XT10/XT10i Fat extractors. It's function is to maintain pressure in the vessel within certain limits during the run and to drain the vessel at the end of the run.
This module is part of the level sensing system in the XT15.
NOTE: Instruments purchased prior to 2012 may have a digital module.
Contact ANKOM Technology at [email protected] if you need assistance to determine which module to order.
Replacement Vent Bottle & Tube Assembly for XT15/XT15i. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle and 6 ft of chemical resistant tubing.
This part is used to filter solvent vapors and should be replaced every 3 months or after 100 instrument operations. This part is only used in the XT15 and XT15I instruments.