This sealing device is used to prevent solution from leaking into the interior cabinet. Refer to A200 Service Procedure 4 or ANKOM Packing Installation Part 1 for installation procedure.
New Bag Suspender design – Ongoing research on the bag suspender suggested a higher degree of level to level variation for some sample types. This led us to develop a new design that would do a better job of controlling the vertical flow to make sure the flow rate is basically the same at each level. This new design is now being shipped with all new A200 and A2000 series fiber analyzers.
If you are planning to order replacement trays for your fiber analyzer with the original design we highly recommend switching to the new design. Where required, we can provide the old design, but you will need to contact us by phone or email to confirm availability.
You CANNOT mix and match the “old” and new style bag suspender trays.
There is no change in pricing for the new design. The new bag suspender will increase precision on a level to level basis for some sample types.
New Bag Suspender design – Ongoing research on the bag suspender suggested a higher degree of level to level variation for some sample types. This led us to develop a new design that would do a better job of controlling the vertical flow to make sure the flow rate is basically the same at each level. This new design is now being shipped with all new A200 and A2000 series fiber analyzers.
If you are planning to order replacement trays for your fiber analyzer with the original design we highly recommend switching to the new design. Where required, we can provide the old design, but you will need to contact us by phone or email to confirm availability.
You CANNOT mix and match the “old” and new style bag suspender trays.
There is no change in pricing for the new design. The new bag suspender will increase precision on a level to level basis for some sample types.
This assembly includes the Bag Suspender and the weight.
New Bag Suspender design – Ongoing research on the bag suspender suggested a higher degree of level to level variation for some sample types. This led us to develop a new design that would do a better job of controlling the vertical flow to make sure the flow rate is basically the same at each level. This new design is now being shipped with all new A200 and A2000 series fiber analyzers.
If you are planning to order replacement trays for your fiber analyzer with the original design we highly recommend switching to the new design. Where required, we can provide the old design, but you will need to contact us by phone or email to confirm availability.
You CANNOT mix and match the “old” and new style bag suspender trays.
There is no change in pricing for the new design. The new bag suspender will increase precision on a level to level basis for some sample types.
The 101.2 Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample.
This part is especially useful during the weighing process.
Inside the zipper bag are desiccant packs that absorb moisture within the bag.
To avoid negatively impacting your assay results with unwanted moisture, use these assemblies to store filter bags while they are cooling after being dried.
This module is part of the level sensing system in the A2000.
NOTE: Instruments purchased prior to 2009 may have a digital module.
Contact ANKOM Technology at [email protected] if you need assistance with determining which module to order.
The agitator moves the bag suspender up and down creating correct flow of solvent in and out of the filter bags during digestion. The packing set prevents the solution from leaking into the interior of the instrument. Refer to A200 Service Procedure 4 or ANKOM Packing Installation Part 1 for installation procedure.
The F12.5 assembly is used in the ANKOM A2000 and A200 fiber instruments.
This hardware is used to hold the digestion trays in place during instrument operation.
The filter bags and trays are made of materials that will float in the detergent solutions used during fiber analyses.
The 639.1 weight is placed on the bag suspender to hold the trays in place during the digestion process in the ANKOM A2000 and A200 fiber instruments.
This sample is to be used with the ANKOM A200/A200I and A2000/A2000I Fiber Analyzers. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, contact ANKOM Technology at [email protected] or call 1-315-986-8090.
The Fiber Optic Cable and Glass Tip functions as an analog level sensor to determine fill volume within the vessel during operation. Refer to Service Procedure AS009 for installation instructions.
Related Documents:
Procedure
Title
Download
09
Level Sensor (Analog) Cable and Glass Tip Replacement
Replacement piston with Viton seal for Burkert solenoid valve.
This valve is used in A2000, A2000I, XT10, XT10I, XT15, XT15I, HCL, HCLI, TDF and TDFI. A2000/A2000I: Part 5678 is found in the Q6 Water Valve and Q7 Vent Valve; refer to Service Procedure AS016 for installation instructions. XT10/XT10I: Part 5678 is found in the Q1, Q2, Q3, Q5 and Q6 valves; refer to Service Procedure XTS005 for installation instructions. XT15/XT15I: Part 5678 is found in the Q1, Q2, Q3, Q4, Q5, Q6 and Q7 valves; refer to Service Procedure XTS005 for installation instructions. HCl: Part 5678 is found in the Q2 valve; refer to Service Procedure 004 for installation instructions. TDF/TDFI: Part 5678 is found in the TDF25.1 - TDF25.4
The Pressure Sensor Assembly is used for measuring the initial pressure prior to the run, and to measure the pressure during a run to monitor the process and ensure proper extraction.
This part goes inside the Solenoid Supply Valves on the XT10, XT15, HCl, A2000 & TDF instruments and is inserted onto the end of the Valve Plunger. Note: XT10 & XT15 - This part seals the water valve to prevent leaking or back flow. For details on replacing this part refer to the following Service Procedures:
This spring goes inside the Solenoid Supply Valves on the XT10, XT15, HCl, A2000 & TDF instruments and is inserted inside the Valve Plunger. Note: XT10 & XT15 - This spring cannot be used in valve Q5. For replacing the Q5 Valve Spring, contact [email protected]. For details on replacing this part refer to the following Service Procedures:
This Viton O-ring is used within the Solenoid Supply Valves on the XT10, XT15, HCl, A2000 & TDF instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide tube. For details on replacing this part refer to the following Service Procedures: