Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
Part #
This 120/220 volt supply provides the correct power to the instrument electronics.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or once...
Part #
This piston is used for high-penetrating solvents and is included in the X55 Kit (XT15/XT15I) and the X73 Kit (XT10/XT10I).
Part #
This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.
Part #
Used within the Extraction Vessel of the XT10/XT10I and XT15/XT15I, this assembly includes a Cup Insert and a Wave Spring Bag Holder.
Part #
This is the internal computer that controls the XT10 Fat Extractor.
Part #
This kit includes replacement pistons for the two solvent valves (Q5 and Q6).
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
This part holds the filter bags within the Cup Insert of your XT10/XT10I and XT15/XT15I.
Part #
This kit is no longer available. However, the components of the X87 kit can be ordered individually as parts 969.5 and 5806. This O-Ring Kit includes an Extraction Vessel seal ( Part #: 969.5 ) and a Cup Insert Top seal ( Part #: 5806 ). Use this kit...
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
Replacement locking Safety Valve Assembly for XT10/XT10I and XT15/XT15I. Refer to Service Procedure Valve Replacement (Safety) (XTS004) for installation instructions.
Part #
This assembly heats the Extraction Chamber of the 120v HCl instrument.
Part #
The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or...
Part #
Before ordering an XT10/XT10I Extractor Vessel, contact our Technical Services Department to confirm your instrument configuration.