Skip to main content

Resource Center

Displaying 1 - 50 of 93
 

Part #

HS

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. ​ The sealer dimensions are: 13.5"L x 4"W x 8"H

Price: $196.00
Quantity:
 

Part #

1916

Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

DELTA
DELTAI

Automated Crude & Detergent Fiber Analysis The ANKOM DELTA Fiber Analyzer automates fiber determinations at the highest level. Capable of Acid Detergent, Neutral Detergent, and Crude Fiber analysis (AOCS Ba 6a-05), the ANKOM DELTA includes an...

 

Part #

TP1

This ink is used by the TN2 numbering machine. It is especially useful for marking the ANKOM Filter Bags because it is chemical resistant.

Price: $26.00
Quantity:
 

Part #

F08

To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.

Price: $14.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 

Part #

D200
D200I

Reliable In-Vitro Incubation The DAISY II Incubator has a demonstrated history of rigorous testing over a broad range of sample types. Labs around the world have achieved results in In Vitro True Digestibility, Apparent Digestibility, Rate studies...

 

Part #

1917

Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

HSi

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...

Price: $196.00
Quantity:
 

Part #

TP3

These un-inked pads are used in conjunction with TP1 in the TN2 marking machine.

Price: $5.00
Quantity:
 

Part #

TN2

This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.

Price: $146.00
Quantity:
 

Part #

X20

The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.

Price: $14.00
Quantity:
 

Part #

6227

This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.

Price: $269.00
Quantity:
 
 
 

Part #

A02

This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...

Price: $728.00
Quantity:
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

X45

The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.

Price: $11.00
Quantity:
 
 
 
 
 
 
 
 

Part #

D17

This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).

Price: $78.00
Quantity:
 
 

Part #

815

This dual voltage fan drives air through the Daisy Incubator (D200/D200I) to maintain consistent heat.

Price: $95.00
Quantity:
 
 
 
 
 
 
 
 

Part #

D2.5

This lid seals the jar during digestion.

Price: $45.00
Quantity:
 
 

Part #

806

These bulbs are used for heating the 220-240v DAISY instrument.

Price: $21.00
Quantity:
 

Part #

808

During digestion, the jars ride on this belt to prevent them from slipping.

Price: $2.00
Quantity:
 

Part #

632

The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...

Price: $40.00
Quantity:
 

Part #

Z132

The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.

Price: $21.00
Quantity:
 

Part #

Z133

This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...

Price: $5.00
Quantity:
 

Part #

DELTA18

The Water Regulator Assembly is found in the DELTA/DELTAI Fiber instruments and helps maintain the appropriate water pressure for rinses and manifold flushing.

Price: $320.00
Quantity:
 

Part #

622

The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.

Price: $33.00
Quantity:
 
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 

Part #

694

This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.

Price: $21.00
Quantity:
 

Part #

5678

The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...

Price: $115.00
Quantity: