Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This 90° Brass Elbow is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments and connects the drain valve to the exhaust hose.
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
If you are using cubitainers for your fiber analyses, the chemicals must move from the cubitainers to the instrument. This tubing connects a cubitainer to port A or B to deliver chemicals to the instrument.
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.
Part #
This quick disconnect fitting mounts onto either side of the upper enclosure of the A2000/A2000I Fiber Analyzers. The part is used to connect to the detergent solution cubitainers.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
The Glass Tip with O-ring is a part of the analog level sensing system in the DELTA/DELTAI, A2000/A2000I Fiber instruments. Found in the Fiber Optic Cable & Glass Tip assembly ( Part #: A32 ), it is used to detect and regulate the fill level within...
Part #
The Copper Water Supply is used to connect the DELTA/DELTAI and A2000/A2000I instruments to the user's water source.
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
The fluid supply distribution manifold directs input fluids to the six IDF/SDF stations. To replace the supply manifold in your instrument, follow TDF Service Procedure Supply Manifold Replacement (TS029).
Part #
The Mixing Pad Assembly may require replacement if bent or if the pad has become loose. Refer to TDF Service Procedure Mixing Pad Adjustment (TS010) to ensure proper alignment.
Part #
This is an enzyme container used for supplying Amylase to the instrument.
Part #
The largest contributor to poor TDF results is the effect of static electricity on the weighing process. The TDF52 Bag Weigh Holder is used during the weighing process to eliminate static electricity while the bag is being weighed.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
The Vacuum Sensor Assembly monitors pressures on the supply lines and is used to identify empty containers, plugged fluid lines, or damage to a supply line. For replacement instructions, refer to Service Procedure Vacuum Sensor Installation (TS013).
Part #
Replacement tube set for all seven pinch valves [Enzymes, IDF inlet(2), SDF Inlet(2) and Waste(2)]. Refer to Service Procedure Tube Replacement (Pinch Valves) (TS005) for installation instructions.
Part #
This clamp bar is used in the IDF part of the instrument to close the top of the Filter Bag.
Part #
This clamp bar is used in the SDF part of the instrument to close the top of the Filter Bag.
Part #
The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...
Part #
This tool is used to view the spray tips for obstructions during cleaning and maintenance.
Part #
The EPDM Tubing is the replacement tube for the HCl / Acetic Acid supply lines. Refer to Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This harness provides power to, and communication from, the pressure sensors.
Part #
This larger 4 liter chemical container is used for supplying buffer to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
The MUX-T board communicates temperature signals to the main controller and is critical in paddle and in-line heat control.
Part #
The MUX-P board communicates pressure signals to the main controller and is critical in accurate pump tube test results, input pressure readings, and vacuum readings during each fluid delivery.
Part #
This product has been replaced by TDF130 . Please note that TDF130 has 75,000 units/g. TDF86 had 100,000 units/g.
Part #
For an existing ANKOM TDF instrument, the TDF65 Codex Method Upgrade kit will be needed to run methods AOAC 2022.01, AOAC 2017.16, AOAC 2011.25, and AOAC 2009.01. This includes: TDF17 Control Panel with Codex method software functionality TDF57...
Part #
The TDF Pressure Sensor Assembly monitors the pressures of the six fluid lines and is used to identify weaknesses in tubing downstream of the peristaltic pump. Refer to TDF Service Procedure Pressure Sensor Replacement (TS011) for installation...
Part #
This filter prevents solid material from entering the instrument through the fluid container.