Part #
Pneumatic Control Solenoid Valve used in TDF and FLEX Instruments. Replacement part for a faulty Solenoid Valve.
Part #
Used for globe vent valve. Located inside the cabinet left side panel.
Part #
For use in the ANKOM FLEX Analyte Extractor. High Strength PTFE magnetic stir-bar; used in each assembled digestion vessel for more difficult to mix samples.
Part #
The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Located in #FLEX30 Slide Valve and #FLEX32 Vent Valve assemblies Rev A.
Part #
The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.
Part #
The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.
Part #
The Waste Bottle Assembly is used to capture waste from the FLEX instrument and includes the waste collection bottle, cap, and tubing.
Part #
The Flask Clip Assemblies are an adhesive-backed spring clip used to secure the round bottom flasks in position again the recovery door.
Part #
The Low Pressure Sensor Assembly is used to monitor nitrogen (N2) line pressure in two locations. One marked 43 monitors N2 going to the four round bottom flasks used for solvent evaporation. One marked 45 monitors N2 Low Pressure and is displayed on...
Part #
The High Pressure Sensor Assembly is used to monitor the main nitrogen input line pressure to the instrument.
Part #
The FLEX21 Thermistor Assemblies are used to monitor temperature at eight locations. One is used to monitor the vessels' temperatures and is marked 46. One is used to monitor the reference temperature surrounding the round bottom flasks and is marked...
Part #
The FLEX Maintenance Kit provides the essential items needed to keep your FLEX Analyte Extractor operating smoohtly. The following items are included: 4 - Container Filters ( Part #: 8202 ) 4 - Vessel Top O-Ring ( Part #: 9231 ) 4 - Column top O-Ring...
Part #
Used with Digestion Vessel Glass ( Part #: FLEX55 ) seal port.
Part #
Small O-ring located in Vessel Bottom Assembly ( Part #: FLEX54 ) on the bottom side.
Part #
Large O-ring located in the Vessel Bottom Assembly ( Part #: FLEX54 ) on the top, inside.
Part #
The Nitrogen Flowmeter is used to regulate nitrogen flow to FLEX instrument.
Part #
This access panel is designed with a viewing window, allowing users to easily monitor their slide valve condition.
Part #
For use in the ANKOM FLEX Analyte Extractor. Virgin PTFE white vessel bottom assembly; used in the digestion step of the analysis. A FLEX54 combined with a FLEX55 form a complete Digestion Vessel Assembly.
Part #
Located in Slide Valve (Part #: FLEX30) and Vent Valve ( Part #: FLEX32 ) assemblies.
Part #
Used in mixer assembly. Located below the Digestion Oven behind the front access panel.
Part #
Used in the Column Nitrogen System, the FLEX71 includes four check valves and connection fittings.
Part #
The Vessel Low Pressure Sensor Assembly is used to monitor pressure in the four vessels during filling and saponification. Specify vessel 1, 2, 3 or 4 at checkout.
Part #
The Optical Bubble Sensor Assemblies function as a drain sensor and monitor fluid lines at five locations. Four sensors are used to confirm drain of the vessels. Those used for vessels 1, 2, 3, and 4 are marked 31, 32, 33,34, respectively. One marked...
Part #
Used only in the cleaning of the Vessel Tops at the end of the run for Fat analyses that use hydrochloric acid (HCl). Procedure for use is available in the FLEX Operator's Manual.
Part #
The Vessel Bottom Plug is used during the Solution Delivery Calibration of the FLEX liquid pump. It is used to seal the bottom hole of the Vessel Bottom Assembly ( Part #: FLEX54 ).
Part #
The fluid supply distribution manifold directs input fluids to the six IDF/SDF stations. To replace the supply manifold in your instrument, follow TDF Service Procedure Supply Manifold Replacement (TS029).
Part #
The Mixing Pad Assembly may require replacement if bent or if the pad has become loose. Refer to TDF Service Procedure Mixing Pad Adjustment (TS010) to ensure proper alignment.
Part #
This is an enzyme container used for supplying Amylase to the instrument.
Part #
The largest contributor to poor TDF results is the effect of static electricity on the weighing process. The TDF52 Bag Weigh Holder is used during the weighing process to eliminate static electricity while the bag is being weighed.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
The Vacuum Sensor Assembly monitors pressures on the supply lines and is used to identify empty containers, plugged fluid lines, or damage to a supply line. For replacement instructions, refer to Service Procedure Vacuum Sensor Installation (TS013).
Part #
Replacement tube set for all seven pinch valves [Enzymes, IDF inlet(2), SDF Inlet(2) and Waste(2)]. Refer to Service Procedure Tube Replacement (Pinch Valves) (TS005) for installation instructions.
Part #
This clamp bar is used in the IDF part of the instrument to close the top of the Filter Bag.
Part #
This clamp bar is used in the SDF part of the instrument to close the top of the Filter Bag.
Part #
The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...
Part #
This tool is used to view the spray tips for obstructions during cleaning and maintenance.
Part #
The EPDM Tubing is the replacement tube for the HCl / Acetic Acid supply lines. Refer to Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This harness provides power to, and communication from, the pressure sensors.
Part #
This larger 4 liter chemical container is used for supplying buffer to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.