Part #
The fluid supply distribution manifold directs input fluids to the six IDF/SDF stations. To replace the supply manifold in your instrument, follow TDF Service Procedure Supply Manifold Replacement (TS029).
Part #
The Mixing Pad Assembly may require replacement if bent or if the pad has become loose. Refer to TDF Service Procedure Mixing Pad Adjustment (TS010) to ensure proper alignment.
Part #
This is an enzyme container used for supplying Amylase to the instrument.
Part #
The largest contributor to poor TDF results is the effect of static electricity on the weighing process. The TDF52 Bag Weigh Holder is used during the weighing process to eliminate static electricity while the bag is being weighed.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
The Vacuum Sensor Assembly monitors pressures on the supply lines and is used to identify empty containers, plugged fluid lines, or damage to a supply line. For replacement instructions, refer to Service Procedure Vacuum Sensor Installation (TS013).
Part #
Replacement tube set for all seven pinch valves [Enzymes, IDF inlet(2), SDF Inlet(2) and Waste(2)]. Refer to Service Procedure Tube Replacement (Pinch Valves) (TS005) for installation instructions.
Part #
This clamp bar is used in the IDF part of the instrument to close the top of the Filter Bag.
Part #
This clamp bar is used in the SDF part of the instrument to close the top of the Filter Bag.
Part #
The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...
Part #
This tool is used to view the spray tips for obstructions during cleaning and maintenance.
Part #
The EPDM Tubing is the replacement tube for the HCl / Acetic Acid supply lines. Refer to Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This harness provides power to, and communication from, the pressure sensors.
Part #
This larger 4 liter chemical container is used for supplying buffer to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
The MUX-T board communicates temperature signals to the main controller and is critical in paddle and in-line heat control.
Part #
The MUX-P board communicates pressure signals to the main controller and is critical in accurate pump tube test results, input pressure readings, and vacuum readings during each fluid delivery.
Part #
The TDF Pressure Sensor Assembly monitors the pressures of the six fluid lines and is used to identify weaknesses in tubing downstream of the peristaltic pump. Refer to TDF Service Procedure Pressure Sensor Replacement (TS011) for installation...
Part #
This filter prevents solid material from entering the instrument through the fluid container.
Part #
This product has been replaced by TDF130 . Please note that TDF130 has 75,000 units/g. TDF86 had 100,000 units/g.
Part #
For an existing ANKOM TDF instrument, the TDF65 Codex Method Upgrade kit will be needed to run methods AOAC 2022.01, AOAC 2017.16, AOAC 2011.25, and AOAC 2009.01. This includes: TDF17 Control Panel with Codex method software functionality TDF57...
Part #
Replacement quick-release connector insert used on the ends of the supply tubes, which connect into the top of the alcohol, buffer, and water containers. Please specify the color: Blue , Red , Green , or White .
Part #
This is a maintenance tool used to clean the (6) 0.020" (0.5mm) holes in the spray tip.
Part #
Useful in the AOAC 2009.01/2011.25 methods, this cup is used to capture the filtrate that comes through the SDF Filter Bag.
Part #
The TDF120 In-Line heater Core is used to replace leaking brass tubing on the In-Line Heater. It includes connected silicone tubing for ease of installation. The heater cartridge and thermistor (temp sensor) are not included in this assembly.
Part #
The nitrogen check valve prevents fluid back-up from the 12 IDF/SDF delivery lines into the pneumatic lines.
Part #
This is a chemical container used for supplying 95% EtOH to the instrument.
Part #
Before the final weighing step in a Dietary Fiber analysis, the bags must be dried. The TDF50 stainless steel Bag Drying Rack has twelve positions for holding a full set of IDF/SDF bags when drying them in an oven.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
This clamp bar is used in the SDF part of the instrument to close the Filter Bag just above the filter.
Part #
The TDF129 kit provides all the tubing and parts necessary to perform the annual maintenance for a TDF instrument. This includes all the supply tubing, delivery tubing, enzyme tubing, and all related tubing plus several parts that can fatigue over...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
Replacement quick-release connector used in the top of the alcohol, buffer, and water containers, as well as in the enzyme bracket.
Part #
The pneumatically operated Pinch Valve-Waste regulates the flow of fluids to the Waste tube during line charges, flushing, and diagnostic operations. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.
Part #
This is a chemical container used for supplying HCl to the instrument.
Part #
The Mixer Piston Assembly is a pneumatic mixer which operates the paddle bar, ensuring good sample agitation during digestion.
Part #
This kit includes six replacement tubes for the peristaltic pump. Refer to TDF Service Procedure Tube Replacement (Silicone Pump Tubes) (TS003) for installation instructions.
Part #
The Flush Tubing Assembly used primarily for maintenance flushing of the fluid lines which allows the user to bypass fluid containers and connect to a single supply container.
Part #
This clamp bar is used in the IDF part of the instrument to close the Filter Bag just above the filter.
Part #
Replacement silicone supply line tubing (uncut) for 1/4" OD silicone tubing. Refer to TDF Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This replacement kit includes a Fill Nozzle, retaining ring, and a spring. For replacement instructions, refer to Service Procedure Fill Nozzle Installation (TS014).
Part #
This corrosion-resistant PEEK valve body and stainless piston is the mechanical component of the Buffer supply valve as of November 2022. It is used as a replacement component for the Water, Buffer, EtOH78, and EtOH95 supply valves. It includes the...
Part #
This container is used to hold the Buffer for TDF CODEX methods.
Part #
This tube replacement set is used as part of preventative maintenance and includes pre-cut, bagged, and labeled lengths of silicone tubing (3/16”OD x 1/16”ID) used in the delivery of reagents in the ANKOM TDF Dietary Fiber Analyzer.