Part #
Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, and 5000 quantities...
Part #
Order F58 Filter Bags by 100 count package quantity (e.g. 10 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, and 5000 quantities. The F58 filter bag is mainly designed for...
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This assembly includes a probe that provides an accurate temperature to the Athena controller.
Part #
This assembly connects the pressure switch to the digestion vessel.
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.
Part #
The Kynar Tip and Washer assembly is used when the Kynar tip has become worn. It is located at the bottom of the bag suspender used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. A worn tip can inhibit proper agitation and...
Part #
This part protects the 120v A200 instrument against power surges that are out-of-specification.
Part #
To protect the interior of the instrument, this collection chamber catches fluid in the event of an internal leak.
Part #
This assembly shows if the packing has started to leak.
Part #
This assembly heats the digestion vessel in the 220v A200I instrument.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Hinge Block Assembly is found in the A200/A200I Fiber Instruments. The assembly includes a shoulder bolt and is used to secured the lid to the vessel during sample digestion.
Part #
This hose carries waste from the vessel to the outer exhaust hose. Includes hose with clips.
Part #
This assembly heats the digestion vessel in the 120v instrument.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This switch turns power on and off to the instrument.
Part #
This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 is a permanent ink pen made of rigid nylon. With an ultrafine tip, writing in small spaces is simple. It is used for precise labeling of various...
Part #
The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
Part #
This switch turns the heat to the digestion vessel on and off.
Part #
The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...
Part #
This assembly includes the handle and clamping device used for sealing the lid and hinge block assembly to the vessel.
Part #
This motor agitates the bag suspender at the proper RPM in the 120v instrument.
Part #
This switch turns the agitation to the digestion vessel on and off.
Part #
The Agitator with Packing Set is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. This is used to replace a worn or pitted agitator and with the packing set creates a seal to keep solution from leaking from the vessel into the...
Part #
The Lid & Hinge Block Assembly is found in the A200/A200I Fiber Instruments. Together, these seal the vessel during sample digestion. The assembly includes both the lid and the hinge block that secures the lid closed, as well as two replacement...
Part #
This assembly includes the O-ring used to seal the digestion vessel and the glue to secure the O-ring.