Instruments
Product Categories
Resources
Part #
Automated Saponification to Isolation The ANKOM FLEX Analyte Extractor's innovative design and automated technology supports multiple analysis configurations and preparation: Vitamin & Cholesterol methods based on: AOAC 2011.07, EN-12823-1, EN-12822...
Part #
Automated Dietary Fiber Analysis Automates AOAC 985.29, 991.43, and 2001.03 (AACC 32-07.01), and NMKL 129, 2003, AOAC 2009.01, 2011.25, 2017.16 and 2022.01 The ANKOM TDF Dietary Fiber Analyzer creates a new standard used for nutritional labeling...
Part #
Automated Crude & Detergent Fiber Analysis The ANKOM DELTA Fiber Analyzer automates fiber determinations at the highest level. Capable of Acid Detergent, Neutral Detergent, and Crude Fiber analysis (AOCS Ba 6a-05), the ANKOM DELTA includes an...
Part #
Semi-Automated Crude & Detergent Fiber Performs AOCS Ba 6a-05 Crude Fiber, Acid Detergent Fiber, and Neutral Detergent Fiber analyses for all feeds and forages. The ANKOM 200 Fiber Analyzer has been subjected to rigorous testing over a broad range of...
Part #
Automated Crude Fat Extraction Official Crude Fat Extraction Method AOCS Am 5-04 The ANKOM XT15 Extractor provides a solution for efficient and economical solvent extraction in fat/oil analysis. Fat ranges from 0% to 100% have been accurately...
Part #
Automated Total Fat Extraction The ANKOM HCl Hydrolysis System provides an easy method for performing the hydrolysis step in total fat/oil analysis . Filter Bag Technology prevents sample transfer errors and allows for batch hydrolysis of up to 15...
Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
Reliable In-Vitro Incubation The DAISY II Incubator has a demonstrated history of rigorous testing over a broad range of sample types. Labs around the world have achieved results in In Vitro True Digestibility, Apparent Digestibility, Rate studies...
Part #
Wireless Gas Production Measurement The ANKOM RF Gas Production System provides an easy-to-use method for monitoring and measuring gas production. Samples and microbes (or other fermentation sources) are placed in the bottles; the RF sensor module is...
Part #
RF1X Gas Production Modules can be added to an ANKOM RF Gas Production System (Base Kit). A total of 50 modules can be connected to a GEN 3 RFS system. Please specify a bottle type. NOTE: Standard RF1X modules come with 250ml bottles. For different...
The ANKOM 2000 and 2000I Fiber Analyzers have been discontinued. The replacement products are the DELTA and DELTAI . ANKOM will continue to supply service and parts for the 2000 and 2000I Fiber Analyzers.
The ANKOM XT10 and XT10I Fat Extractors have been discontinued. The replacement products are the XT15 and XT15I . ANKOM will continue to supply service and parts for the XT10 and XT10I Fat Extractors.
Part #
Replacement quick-release connector insert used on the ends of the supply tubes, which connect into the top of the alcohol, buffer, and water containers. Please specify the color: Blue , Red , Green , or White .
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
This is a maintenance tool used to clean the (6) 0.020" (0.5mm) holes in the spray tip.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
The Chemical Receptacle is used to house an NaOH (or stronger Base) when performing oxygen consumption studies. The function of the Base material is to scavenge the CO2 produced by the aerobic metabolism. This produces a negative pressure as the O2...
Part #
The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.
Part #
Useful in the AOAC 2009.01/2011.25 methods, this cup is used to capture the filtrate that comes through the SDF Filter Bag.
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
This quick disconnect fitting mounts onto either side of the upper enclosure of the A2000/A2000I Fiber Analyzers. The part is used to connect to the detergent solution cubitainers.
Part #
The replacement Hose Coupler is used on the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. It connects to the drain hose at the side of the instrument. Includes 2 pieces.
Part #
Two versions of software are available depending on the RFS#: RF3: RF GPM Software 11.4 RF3X: RF GPM Software 15.0 This update to the GPM software is a major enhancement that includes many new features including: Enables up to 10 systems in one...
Part #
The TDF120 In-Line heater Core is used to replace leaking brass tubing on the In-Line Heater. It includes connected silicone tubing for ease of installation. The heater cartridge and thermistor (temp sensor) are not included in this assembly.
Part #
The Tubing Seal, 3x8 mm is used within the RF1X module to secure and seal the Pressure Sensor ( Part #: RF31 ) and Viton-Silicone Tube ( Part #: RF11 ) into their respective ports in the bottom of the module housing.
Part #
Used for globe vent valve. Located inside the cabinet left side panel.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used daily or...
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or...
Part #
For use in the ANKOM FLEX Analyte Extractor. High Strength PTFE magnetic stir-bar; used in each assembled digestion vessel for more difficult to mix samples.
Part #
This 120/220 volt supply provides the correct power to the instrument electronics.
Part #
The diffuse is a fiber glass filter disc used in the ANKOM FLEX Analyte Extractor to assist with the filtration of certain sample types.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Add 20L of1N-H2SO4 Sulfuric Acid to FAD20C Powder to make the Acid Detergent solution used in the Acid Detergent Fiber method. Refer to the ANKOM A2000 Operator's Manual for the correct formulation.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. This assembly includes the latch that secures the lid to the instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.
Part #
The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.
Part #
Attaches on the top of the RD/RDI Dryer. This filter is used when drying filter bags before and after a fat extraction done with an ANKOM XT10/XT10I or an ANKOM XT15/XT15I Extractor.
Part #
The RF Gas Production System bottles that include a septa port use a 3 mm 2-sided PTFE coated Silicone Septa to provide an easy to penetrate seal while providing minimal pressure loss per penetration. The RF35 pack includes 10 septa.
Part #
The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...
Part #
The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
The 9001 column funnel is an adapter funnel used when running a total fat extraction in an ANKOM FLEX Analyte Extractor.
Part #
For use in the ANKOM FLEX Analyte Extractor. One fat filter is used in each digestion vessel for a fat analysis.