Skip to main content

Resource Center

Displaying 1 - 50 of 168

Part #

F57

Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000...

Price: $256.00
Quantity:
 

Part #

F58

Order F58 Filter Bags by 100 count package quantity (e.g. 10 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000 quantities. The F58 filter bag is mainly designed...

Price: $157.00
Quantity:
 

Part #

DF-FT

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section when only a Total Dietary Fiber (TDF) value is required. The DF-FT bag allows the entire contents of the enzymatic digestion to Flow Thru to the lower SDF chamber...

Price: $100.00
Quantity:
 

Part #

DF-I

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section to capture the Insoluble Dietary Fiber after the enzymatic digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six 50-count packs...

Price: $250.00
Quantity:
 

Part #

DF-S

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the lower section to capture and precipitate the Soluble Dietary Fiber (SDF) after the IDF digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six...

Price: $250.00
Quantity:
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 

Part #

HS

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. ​ The sealer dimensions are: 13.5"L x 4"W x 8"H

Price: $196.00
Quantity:
 

Part #

1916

Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

X45

The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.

Price: $11.00
Quantity:
 

Part #

HSi

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...

Price: $196.00
Quantity:
 

Part #

1917

Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

632

The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...

Price: $40.00
Quantity:
 

Part #

6227

This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.

Price: $269.00
Quantity:
 

Part #

Z132

The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.

Price: $21.00
Quantity:
 

Part #

TP1

This ink is used by the TN2 numbering machine. It is especially useful for marking the ANKOM Filter Bags because it is chemical resistant.

Price: $26.00
Quantity:
 

Part #

Z133

This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...

Price: $5.00
Quantity:
 
 
 

Part #

DELTA18

The Water Regulator Assembly is found in the DELTA/DELTAI Fiber instruments and helps maintain the appropriate water pressure for rinses and manifold flushing.

Price: $320.00
Quantity:
 

Part #

622

The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.

Price: $33.00
Quantity:
 

Part #

A02

This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...

Price: $728.00
Quantity:
 
 

Part #

640

The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...

Price: $23.00
Quantity:
 

Part #

692

The Drip Tray is part of the Maintenance Alert Assembly and is used in the DELTA, A200, and A2000 instruments. It functions as a collector for a fluid leak around the agitator, diverting it away from the motor.

Price: $7.00
Quantity:
 

Part #

693

This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.

Price: $26.00
Quantity:
 

Part #

638.7

The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.

Price: $16.00
Quantity:
 

Part #

F08

To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.

Price: $14.00
Quantity:
 

Part #

F11

The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.

Price: $259.00
Quantity:
 

Part #

F26

The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...

Price: $65.00
Quantity:
 

Part #

DELTA01

The DELTA01 Maintenance Alert Assembly is used in the DELTA and A2000 instruments. It includes the Drip Tray w/plugged drain hole ( Part #: 692 ), Agitator Apron ( Part #: 638.7 ), and brass washer and functions as a collector for a fluid leak...

Price: $37.00
Quantity:
 

Part #

460

This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.

Price: $41.00
Quantity:
 

Part #

Z557

The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.

Price: $18.00
Quantity:
 

Part #

DELTA17

The Pressure Sensor Assembly is used in the DELTA & DELTAI Fiber instruments for measuring the initial pressure before a run. It also measures the pressure during a run to monitor the process and ensure proper extraction.

Price: $142.00
Quantity:
 

Part #

DELTA19

The Splat Controller w/ Spice Board is used in the DELTA Fiber instrument and holds the program, controlling all funtions of the DELTA instrument.

Price: $450.00
Quantity:
 

Part #

6058

The Vessel O-Ring is used in DELTA/DELTAI and A2000/A2000I vessel lids to seal the vessel during digestion.

Price: $17.00
Quantity:
 

Part #

6068

The Timing Belt drives the agitator in the DELTA/DELTAI and A2000/A2000I Fiber instruments.

Price: $12.00
Quantity:
 
 

Part #

461

This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.

Price: $51.00
Quantity:
 

Part #

A17

The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.

Price: $131.00
Quantity:
 

Part #

A20

The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.

Price: $839.00
Quantity:
 

Part #

F12

The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.

Price: $60.00
Quantity:
 

Part #

F12.5

The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...

Price: $44.00
Quantity:
 

Part #

X20

The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.

Price: $14.00
Quantity:
 

Part #

639.1

The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...

Price: $49.00
Quantity:
 
 

Part #

6035

This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.

Price: $2.00
Quantity:
 

Part #

DELTA12

The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.

Price: $810.00
Quantity: