Part #
This is a chemical container used for supplying Buffer to the instrument.
Part #
This is a chemical container used for supplying Deionized Water to the instrument.
Part #
The last step in the Dietary Fiber extraction process is to rinse the samples with acetone. That process is not done on the ANKOM TDF instrument. The TDF51 Bag Rinse Stand is used to hold the Filter Bags during an Acetone Rinse.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
This tube replacement set is used as part of preventative maintenance and includes precut, bagged, and labeled lengths of silicone tubing (1/4”OD x 1/8”ID) used in the supply of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
This larger 4 liter chemical container is used for supplying EtOH78 to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This larger 10 liter chemical container is used for supplying EtOH95 to the instrument. The larger size accommodates 4 runs on the instrument before refilling is necessary.
Part #
This part protects the 120v instrument against power surges that are out-of-specification.
Part #
Power Supply B is a transformer that supplies 25v DC power to the solenoid valves and paddle heaters. This comes with an in-line fuse kit for overload protection and is used for both 110v and 220v instruments.
Part #
The High Pressure Sensor monitors pressure on the intake nitrogen line.
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
This corrosion-resistant PEEK valve body and stainless piston is the mechanical component of the Buffer supply valve as of November 2022. It is used as a replacement component for the Water, Buffer, EtOH78, and EtOH95 supply valves. It includes the...
Part #
This container is used to hold the Buffer for TDF CODEX methods.
Part #
This tube replacement set is used as part of preventative maintenance and includes pre-cut, bagged, and labeled lengths of silicone tubing (3/16”OD x 1/16”ID) used in the delivery of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
Pneumatic Control Solenoid Valve used in TDF and FLEX Instruments. Replacement part for a faulty Solenoid Valve.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
Replacement quick-release connector used in the top of the alcohol, buffer, and water containers, as well as in the enzyme bracket.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
This holder is used to position the HCl container in the appropriate location next to the instrument.
Part #
This part protects the 220v instrument against power surges that are out-of-specification.
Part #
This is the Low Pressure Regulator for the TDF instrument.
Part #
Individual replacement paddle for the ANKOM TDF paddle bar. Includes embedded temperature sensor and heater cartridge.
Part #
This filter prevents solid material from entering the instrument through the fluid container.
Part #
The pneumatically operated Pinch Valve-Waste regulates the flow of fluids to the Waste tube during line charges, flushing, and diagnostic operations. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.
Part #
This is a chemical container used for supplying HCl to the instrument.
Part #
The Mixer Piston Assembly is a pneumatic mixer which operates the paddle bar, ensuring good sample agitation during digestion.
Part #
This kit includes six replacement tubes for the peristaltic pump. Refer to TDF Service Procedure Tube Replacement (Silicone Pump Tubes) (TS003) for installation instructions.
Part #
The Flush Tubing Assembly used primarily for maintenance flushing of the fluid lines which allows the user to bypass fluid containers and connect to a single supply container.
Part #
This clamp bar is used in the IDF part of the instrument to close the Filter Bag just above the filter.
Part #
Replacement silicone supply line tubing (uncut) for 1/4" OD silicone tubing. Refer to TDF Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This replacement kit includes a Fill Nozzle, retaining ring, and a spring. For replacement instructions, refer to Service Procedure Fill Nozzle Installation (TS014).
Part #
This is a set of replacement Enzyme Tubes used in the ANKOM TDF instrument.
Part #
When unscrewed, these screws (two total - one on each side of the ANKOM TDF Dietary Fiber Analyzer) allow the instrument to tilt forward for convenient access to the back.
Part #
The TDF104 Barb Fittings are used as connectors for tubing in the ANKOM TDF instrument. This package includes 12 fittings.
Part #
The TDF105 Nylon Hex Nut pack includes 12 nuts for use in the ANKOM TDF instrument.
Part #
This larger 4 liter chemical container is used for supplying distilled water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This is the High Pressure Regulator for the TDF instrument.
Part #
Power Supply A is a 10 amp transformer that supplies 24v DC power to the pump motor controller (PMC) and analog multiplexer boards MUX-T ( Part #: TDF111 ) and MUX-P ( Part #: TDF112 ). This supply is used for both 110v and 220v instruments.
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
This is an enzyme container used for supplying Protease to the instrument.
Part #
This is a chemical container used for supplying 78% EtOH to the instrument.
Part #
The Safety Cover with Handle is used to prevent incidental splashing of fluids and assists with preventing drafts during bag heating.
Part #
Replacement silicone tubing (uncut) for all 3/16" OD tubing. Refer to TDF Service Procedure Tube Replacement (Delivery) (TS006) for installation instructions.
Part #
Waste fluids flow through the Drain Tray Tube from the instrument to a waste drain or container. The Drain Tray Tube Kit comes with 6 ft. of Drain Tube, (1) 6138 Tube Clamp, (2) 8288 Elbow Connectors, and (1) 8133 Adhesive Clamp that is used to hold...