Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
The Water Regulator Assembly is found in the DELTA/DELTAI Fiber instruments and helps maintain the appropriate water pressure for rinses and manifold flushing.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This 90° Brass Elbow is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments and connects the drain valve to the exhaust hose.
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
Part #
The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
Part #
The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...
Part #
The DELTA01 Maintenance Alert Assembly is used in the DELTA and A2000 instruments. It includes the Drip Tray w/plugged drain hole ( Part #: 692 ), Agitator Apron ( Part #: 638.7 ), and brass washer and functions as a collector for a fluid leak...
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
The Pressure Sensor Assembly is used in the DELTA & DELTAI Fiber instruments for measuring the initial pressure before a run. It also measures the pressure during a run to monitor the process and ensure proper extraction.
Part #
The Splat Controller w/ Spice Board is used in the DELTA Fiber instrument and holds the program, controlling all funtions of the DELTA instrument.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
The Vessel O-Ring is used in DELTA/DELTAI and A2000/A2000I vessel lids to seal the vessel during digestion.
Part #
The Timing Belt drives the agitator in the DELTA/DELTAI and A2000/A2000I Fiber instruments.
Part #
The Temperature Controller is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments and maintains vessel temperature during digestion.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This relay replaces Part #: 6114 and controls power to the Ascon temperature controller, motor, and drain valve on the DELTA/DELTAI and A2000/A2000I Fiber instruments, as well as the HCl/HClI instrument.
Part #
The A10 Motor Assembly 220v drives the agitation system in the 220v DELTAI & A2000I.
Part #
This kit and the accompanying process guide provide the parts and the instructions to complete the Preventative Maintenance (PM) process for the DELTA or A2000 Automated Fiber Analyzers. This procedure should be completed annually for an instrument...
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.