Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
This drive belt connects the motor and the drive roller ( Part #: 834 ).
Part #
This part protects the D200/D200I instruments against power surges that are out-of-specification.
Part #
Replacement fused filter plug and on/off switch.
Part #
This drive roller connects the motor to the drive pulleys.
Part #
This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
This probe provides an accurate temperature to the Athena controller.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This assembly includes a probe that provides an accurate temperature to the Athena controller.
Part #
This assembly connects the pressure switch to the digestion vessel.
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
Replacement programmed controller for the D200/D200I Daisy II Incubator. For installation instructions, refer to DAISY Service Procedure Controller Installation (DS002).
Part #
This vent valve is used in the jar lid ( Part #: D2.5 ) for releasing pressure from the jars during digestion.
Part #
During digestion, the jars ride on this belt to prevent them from slipping.
Part #
This assembly heats the digestion vessel in the 220v A200I instrument.
Part #
The Outer Exhaust Hose Assembly is used in the DELTA/DELTAI and A200/A200I Fiber instruments. It drains waste solutions from the digestion vessel.
Part #
The Bag Suspender Rod w/ Nut Assembly is used when damage to the rod or pitting has occurred. It runs through the middle of the bag suspender and holds the nine trays in place and is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber...
Part #
The Hinge Block Assembly is found in the A200/A200I Fiber Instruments. The assembly includes a shoulder bolt and is used to secured the lid to the vessel during sample digestion.
Part #
This hose carries waste from the vessel to the outer exhaust hose. Includes hose with clips.
Part #
This assembly heats the digestion vessel in the 120v instrument.
Part #
The Bag Weight Machined is used on the top of the bag suspender within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is necessary to hold the trays in place, which, in turn, hold the filter bags in suspension, during the digestion...