The Low Pressure Sensor Assembly is used to monitor nitrogen (N2) line pressure in two locations. One marked 43 monitors N2 going to the four round bottom flasks used for solvent evaporation. One marked 45 monitors N2 Low Pressure and is displayed on...
Part #
The High Pressure Sensor Assembly is used to monitor the main nitrogen input line pressure to the instrument.
Part #
The Vessel Low Pressure Sensor Assembly is used to monitor pressure in the four vessels during filling and saponification. Specify vessel 1, 2, 3 or 4 at checkout.
Part #
The Motor with 4-wire cable is a stepper motor which operates the vessels' magnetic stirrers.
Part #
The FLEX21 Thermistor Assemblies are used to monitor temperature at eight locations. One is used to monitor the vessels' temperatures and is marked 46. One is used to monitor the reference temperature surrounding the round bottom flasks and is marked...
Part #
The Optical Bubble Sensor Assemblies function as a drain sensor and monitor fluid lines at five locations. Four sensors are used to confirm drain of the vessels. Those used for vessels 1, 2, 3, and 4 are marked 31, 32, 33,34, respectively. One marked...
Part #
The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.
Part #
The FLEX24 High Temperature Thermistor Assembly is marked 56 and is used to monitor the temperature within the oven.
Part #
The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.
Part #
The FLEX-SPE-02 is for use in the ANKOM FLEX Analyte Extractor. The column contains silica-based sorbent material and is used in the extraction step of the instrument for a total fat analysis.
Part #
The 9001 column funnel is an adapter funnel used when running a total fat extraction in an ANKOM FLEX Analyte Extractor.
Part #
The RF Gen 3 Circuit Board contains the electronics used for communication with all RF1X / RF5X modules.
Part #
The RF Solenoid assembly is used to replace a faulty solenoid pinch valve within the RF1 or RF1X Module.
Part #
The FLEX Maintenance Kit provides the essential items needed to keep your FLEX Analyte Extractor operating smoohtly. The following items are included: 4 - Container Filters ( Part #: 8202 ) 4 - Vessel Top O-Ring ( Part #: 9231 ) 4 - Column top O-Ring...
Part #
This adapter lid with GL45 threads allows RF Modules to fit 1.8L wide mouth jar ( Part #: 7181 ).
Part #
This part displays the solvent level on the XT15/XT15I instruments.
Part #
Used only in the cleaning of the Vessel Tops at the end of the run for Fat analyses that use hydrochloric acid (HCl). Procedure for use is available in the FLEX Operator's Manual.
Part #
This tube replacement set is used as part of preventative maintenance and includes precut, bagged, and labeled lengths of silicone tubing (1/4”OD x 1/8”ID) used in the supply of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
This tube replacement set is used as part of preventative maintenance and includes pre-cut, bagged, and labeled lengths of silicone tubing (3/16”OD x 1/16”ID) used in the delivery of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
For use in the ANKOM FLEX Analyte Extractor. One fat filter is used in each digestion vessel for a fat analysis.
Part #
Used in older XT15/XT15I. Please contact ANKOM for more information.
Part #
The TDF129 kit provides all the tubing and parts necessary to perform the annual maintenance for a TDF instrument. This includes all the supply tubing, delivery tubing, enzyme tubing, and all related tubing plus several parts that can fatigue over...
Part #
The Amylase Dispenser connects to the DELTA/DELTAI instrument and is used as a reservoir to dispense amylase into the vessel for digestion of starch during a Neutral Detergent fiber analysis.
Part #
The DELTA01 Maintenance Alert Assembly is used in the DELTA and A2000 instruments. It includes the Drip Tray w/plugged drain hole ( Part #: 692 ), Agitator Apron ( Part #: 638.7 ), and brass washer and functions as a collector for a fluid leak...
Part #
This software enables a user the ability to use the "Custom" feature on the instrument. This allows for the creation of new, original methods for research and development. Please provide your instrument serial number when ordering.
Part #
This drive roller connects the motor to the drive pulleys.
Part #
This software enables a user the ability to run the Total Fat and Crude Fat method. These methods are applicable to oil, food, feed, and liquid samples. Please provide your instrument serial number when ordering.
Part #
This software enables a user the ability to run the Vitamins and Cholesterol method. This method is used to isolate Vitamin A, E, D, and Cholesterol within a given method. This method applies to food and feed samples. Please provide your instrument...
Part #
The SPE-02 Container is used in crude fat analyses on the ANKOM FLEX Analyte Extractor.
Part #
This 5 cm Cellulose Filter is used in additon to other filters to filter fine particulate in the FLEX Analyte Extractor's digestion vessels. One application includes crude fat analysis.
Part #
The Vessel Bottom Plug is used during the Solution Delivery Calibration of the FLEX liquid pump. It is used to seal the bottom hole of the Vessel Bottom Assembly ( Part #: FLEX54 ).
Part #
Pneumatic Control Solenoid Valve used in TDF and FLEX Instruments. Replacement part for a faulty Solenoid Valve.
Part #
This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
Part #: A29 is not available for purchase on the web. For assistance, please contact ANKOM Technology .
Part #
This larger 4 liter chemical container is used for supplying deionized water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
Replacement set of red light bulb and ceramic heater (50w/220v) for improved heating of D200i chamber. Sold as set only.
Part #
This larger 4 liter chemical container is used for supplying buffer to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This larger 4 liter chemical container is used for supplying EtOH78 to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This larger 10 liter chemical container is used for supplying EtOH95 to the instrument. The larger size accommodates 4 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the HCl container in the appropriate location next to the instrument.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This part protects the 120v instrument against power surges that are out-of-specification.
Part #
This part protects the 220v instrument against power surges that are out-of-specification.