Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...
Part #
ANKOM FCFB20CB and FCFA20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment
Part #
Among other uses, acetone is used as the last rinse in a Dietary Fiber analysis. The FACE product is packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
Before doing a dietary fiber assay, you should label the filter bags in order to properly record results. Use this marker for labeling the filter bags.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The TCH2 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Chiller can support up to two extractors at the same time. • 0°...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
This 230v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
This 115v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
ANKOM FND20 provides laboratories with a quick, convenient and economical way to assure consistent, high quality Neutral Detergent Fiber determination results. *Special handling required for International Shipment
Part #
F1N is reagent grade 1N Sulfuric Acid. The product comes in 1 Liter Bottles and is sold in quantities of 4. *Special handling is required for International Shipments
Part #
Among other uses, sulfuric acid is used in a lignin determination. FSA-72 is 72% sulfuric acid packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
ANKOM FCFA20CB and FCFB20CB provide laboratories with a quick, convenient and economical way to assure consistent, high quality Crude Fiber determination results. *Special handling required for International Shipment Warning: This product can expose...
Part #
Combine all FND20C with the accompanying triethylene glycol and add 20L of Distilled Water to make the Neutral Detergent Solution. If you remove only a portion of the dry chemicals to make less than 20L of solution, it is impossible to know if the...
Part #
ANKOM FAD20CB provides laboratories with a quick, convenient and economical way to assure consistent, high quality Acid Detergent Fiber determination results. *Special handling required for International Shipment
Part #
ANKOM FCFB20 when diluted provides 20 L of solution for part B of the Crude Fiber method. *Special handling required for International Shipment
Part #
Triethylene glycol (FNDTG) combined with FND20C and Distilled Water make up Neutral Detergent Solution.
Part #
ANKOM FCFA20 when diluted provides 20 L of solution for part A of the Crude Fiber method. *Special handling required for International Shipment
Part #
Add 20L of1N-H2SO4 Sulfuric Acid to FAD20C Powder to make the Acid Detergent solution used in the Acid Detergent Fiber method. Refer to the ANKOM A2000 Operator's Manual for the correct formulation.
Part #
DE1 contains 125 grams of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE1 SDS information.
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
FAD20 contains four 1 L bottles of liquid concentrate. Each bottle can be diluted with water to make 5 liters of solution. When diluted, the solution is ready for use in the Acid Detergent method. *Special handling required for International Shipment
Part #
RF1X Gas Production Modules can be added to an ANKOM RF Gas Production System (Base Kit). A total of 50 modules can be connected to a GEN 3 RFS system. Please specify a bottle type. NOTE: Standard RF1X modules come with 250ml bottles. For different...
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
The RF Gas Production System uses rechargeable battery packs ( #RF16 / #RF46 ). The RF25 10-Station Battery Charger is used to charge the RF16/RF46 Rechargeable Battery Packs. As the name says, this charger can charge 10 batteries at one time.
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
The Temperature Probe w/ ground terminal is used in the DELTA/DELTAI and A2000/A2000I Fiber instruments. This probe provides an accurate vessel temperature which is displayed on the Ascon controller.
Part #
The Lid Assembly is used on the DELTA/DELTAI and A2000/A2000I Fiber instruments and seals the top of the digestion vessel.