Part #
Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
This drive belt connects the motor and the drive roller ( Part #: 834 ).
Part #
This part protects the D200/D200I instruments against power surges that are out-of-specification.
Part #
Replacement fused filter plug and on/off switch.
Part #
This drive roller connects the motor to the drive pulleys.
Part #
This is a 100 hr timer assembly for monitoring incubation times of samples in the ANKOM Daisy II Incubator (D200/D200I).
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
This probe provides an accurate temperature to the Athena controller.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.
Part #
Used in older XT15/XT15I. Please contact ANKOM for more information.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
Replacement Glass Tip and Fiber Optic Cable to XT15/XT15I level sensor. Refer to Service Procedure Replace X59 Sensor & Cable with Glass Tip (X5S012) for installation instructions.
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used...
Part #
This piston is used for high-penetrating solvents and is included in the X55 Kit (XT15/XT15I) and the X73 Kit (XT10/XT10I).
Part #
This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
The Drain Manifold Assembly is used in the XT15/XT15I Fat Extractors. It receives water from multiple cooling coils and routes it to the waste line.
Part #
Used within the Extraction Vessel of the XT10/XT10I and XT15/XT15I, this assembly includes a Cup Insert and a Wave Spring Bag Holder.
Part #
Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
This part displays the solvent level on the XT15/XT15I instruments.
Part #
Replacement programmed controller for the D200/D200I Daisy II Incubator. For installation instructions, refer to DAISY Service Procedure Controller Installation (DS002).
Part #
This vent valve is used in the jar lid ( Part #: D2.5 ) for releasing pressure from the jars during digestion.
Part #
This part holds the filter bags within the Cup Insert of your XT10/XT10I and XT15/XT15I.