Skip to main content

Resource Center

Displaying 1 - 50 of 100

Part #

FLEX-SPE-02

The FLEX-SPE-02 is for use in the ANKOM FLEX Analyte Extractor. The column contains silica-based sorbent material and is used in the extraction step of the instrument for a total fat analysis.

Price: $849.60
Quantity:
 

Part #

FLEX-CF

This 5 cm Cellulose Filter is used in additon to other filters to filter fine particulate in the FLEX Analyte Extractor's digestion vessels. One application includes crude fat analysis.

Price: $0.75
Quantity:
 
 

Part #

FLEX-SPE-01

For use in the ANKOM FLEX Analyte Extractor. SPE Column contains silica-based sorbent material; used in the extraction step of the instrument for a vitamin or cholesterol analysis. These items are sold in packages of 40.

Price: $266.00
Quantity:
 
 

Part #

FLEX-FF

For use in the ANKOM FLEX Analyte Extractor. One fat filter is used in each digestion vessel for a fat analysis.

Price: $75.00
Quantity:
 

Part #

XT4

Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...

Price: $276.00
Quantity:
 

Part #

FLEX-VF

For use in the ANKOM FLEX Analyte Extractor. One vitamin filter is used in each digestion vessel for a vitamin or cholesterol analysis.

Price: $75.00
Quantity:
 

Part #

FLEX-SDB

The Sorbent Disposal Bags are used to remove any residual solvent left in the sorbent material after a run is complete. The contents of four SPE columns fit into one Sorbent Disposal Bag. For further instructions, follow the FLEX Service Procedure...

Price: $19.00
Quantity:
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 
 
 

Part #

FLEX49

The Waste Bottle Assembly is used to capture waste from the FLEX instrument and includes the waste collection bottle, cap, and tubing.

Price: $157.00
Quantity:
 

Part #

FLEX57

The Flask Clip Assemblies are an adhesive-backed spring clip used to secure the round bottom flasks in position again the recovery door.

Price: $11.00
Quantity:
 

Part #

FLEX55

For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...

Price: $304.00
Quantity:
 

Part #

9364

For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.

Price: $128.00
Quantity:
 

Part #

9148

Located in #FLEX30 Slide Valve and #FLEX32 Vent Valve assemblies Rev A.

Price: $17.00
Quantity:
 

Part #

FLEX23

The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.

Price: $34.00
Quantity:
 

Part #

FLEX32

The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.

Price: $886.00
Quantity:
 

Part #

9415

For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.

Price: $21.00
Quantity:
 

Part #

206

This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.

Price: $3.00
Quantity:
 
 

Part #

X96

This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.

Price: $114.00
Quantity:
 

Part #

F08

To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.

Price: $14.00
Quantity:
 

Part #

X35

Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.

Price: $16.00
Quantity:
 
 

Part #

460

This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.

Price: $41.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

5806

This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.

Price: $6.00
Quantity:
 

Part #

X33

This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used...

Price: $1,148.00
Quantity:
 
 

Part #

FLEX43

The Process Pump is the fluid delivery pump used to deliver all reagents from the reservoirs to the vessels.

Price: $1,182.00
Quantity:
 
 
 

Part #

9313

Used for globe vent valve. Located inside the cabinet left side panel.

Price: $33.00
Quantity:
 
 

Part #

9380

For use in the ANKOM FLEX Analyte Extractor. High Strength PTFE magnetic stir-bar; used in each assembled digestion vessel for more difficult to mix samples.

Price: $21.00
Quantity:
 

Part #

461

This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.

Price: $51.00
Quantity:
 

Part #

X20

The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.

Price: $14.00
Quantity:
 

Part #

X64

The Drain Manifold Assembly is used in the XT15/XT15I Fat Extractors. It receives water from multiple cooling coils and routes it to the waste line.

Price: $165.00
Quantity:
 
 

Part #

X92

Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.

Price: $220.00
Quantity:
 
 
 

Part #

FLEX9

The Low Pressure Sensor Assembly is used to monitor nitrogen (N2) line pressure in two locations. One marked 43 monitors N2 going to the four round bottom flasks used for solvent evaporation. One marked 45 monitors N2 Low Pressure and is displayed on...

Price: $81.00
Quantity:
 
 

Part #

FLEX21

The FLEX21 Thermistor Assemblies are used to monitor temperature at eight locations. One is used to monitor the vessels' temperatures and is marked 46. One is used to monitor the reference temperature surrounding the round bottom flasks and is marked...

Price: $104.00
Quantity: