Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section when only a Total Dietary Fiber (TDF) value is required. The DF-FT bag allows the entire contents of the enzymatic digestion to Flow Thru to the lower SDF chamber...
Part #
For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section to capture the Insoluble Dietary Fiber after the enzymatic digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six 50-count packs...
Part #
For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the lower section to capture and precipitate the Soluble Dietary Fiber (SDF) after the IDF digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
This assembly heats the Extraction Chamber of the 120v HCl instrument.
Part #
The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. This assembly includes the latch that secures the lid to the instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.
Part #
The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.
Part #
This 120/220 volt supply provides the correct power to the instrument electronics.
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
The fluid supply distribution manifold directs input fluids to the six IDF/SDF stations. To replace the supply manifold in your instrument, follow TDF Service Procedure Supply Manifold Replacement (TS029).
Part #
The Mixing Pad Assembly may require replacement if bent or if the pad has become loose. Refer to TDF Service Procedure Mixing Pad Adjustment (TS010) to ensure proper alignment.
Part #
This is an enzyme container used for supplying Amylase to the instrument.
Part #
The largest contributor to poor TDF results is the effect of static electricity on the weighing process. The TDF52 Bag Weigh Holder is used during the weighing process to eliminate static electricity while the bag is being weighed.
Part #
This container is used with the AOAC 2009.01/2011.25 methods.
Part #
The Vacuum Sensor Assembly monitors pressures on the supply lines and is used to identify empty containers, plugged fluid lines, or damage to a supply line. For replacement instructions, refer to Service Procedure Vacuum Sensor Installation (TS013).
Part #
Replacement tube set for all seven pinch valves [Enzymes, IDF inlet(2), SDF Inlet(2) and Waste(2)]. Refer to Service Procedure Tube Replacement (Pinch Valves) (TS005) for installation instructions.
Part #
This clamp bar is used in the IDF part of the instrument to close the top of the Filter Bag.
Part #
This clamp bar is used in the SDF part of the instrument to close the top of the Filter Bag.
Part #
The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...
Part #
This tool is used to view the spray tips for obstructions during cleaning and maintenance.