Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
These pre-inked pads are used by the TN2 numbering machine.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...
Part #
Before doing a dietary fiber assay, you should label the filter bags in order to properly record results. Use this marker for labeling the filter bags.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The TCH2 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Chiller can support up to two extractors at the same time. • 0°...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...
Part #
This 230v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
This 115v Shaker Water Bath can be used to control the temperature and mixing during an assay. Spring fixtures that hold bottles in place (WB-Tray) are sold separately. Specifications for this product can be found in the attached Information Sheet.
Part #
RF1X Gas Production Modules can be added to an ANKOM RF Gas Production System (Base Kit). A total of 50 modules can be connected to a GEN 3 RFS system. Please specify a bottle type. NOTE: Standard RF1X modules come with 250ml bottles. For different...
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
The RF28 Air Purge Assembly can be used to purge the glass bottle prior to an experiment, or to pressurize the module assembly (through the Luer Duckbill Check Valve, Part #: 7139 ) to check for leaks. For module purge instructions, see RF Service...
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This cable is used to connect the Dual Lead Battery Pack ( Part #: RF46 ) to the 10-Station Battery Charger ( Part #: RF25 ). Longer extension cables are available upon request.
Part #
Replacement Glass Tip and Fiber Optic Cable to XT15/XT15I level sensor. Refer to Service Procedure Replace X59 Sensor & Cable with Glass Tip (X5S012) for installation instructions.
Part #
This switch turns power on and off to the instrument.
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
Replacement quick-release connector used in the top of the alcohol, buffer, and water containers, as well as in the enzyme bracket.
Part #
The pneumatically operated Pinch Valve-Waste regulates the flow of fluids to the Waste tube during line charges, flushing, and diagnostic operations. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.
Part #
This is a chemical container used for supplying HCl to the instrument.
Part #
The Mixer Piston Assembly is a pneumatic mixer which operates the paddle bar, ensuring good sample agitation during digestion.
Part #
This kit includes six replacement tubes for the peristaltic pump. Refer to TDF Service Procedure Tube Replacement (Silicone Pump Tubes) (TS003) for installation instructions.
Part #
The Flush Tubing Assembly used primarily for maintenance flushing of the fluid lines which allows the user to bypass fluid containers and connect to a single supply container.
Part #
The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
Part #
This clamp bar is used in the IDF part of the instrument to close the Filter Bag just above the filter.
Part #
Replacement silicone supply line tubing (uncut) for 1/4" OD silicone tubing. Refer to TDF Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This replacement kit includes a Fill Nozzle, retaining ring, and a spring. For replacement instructions, refer to Service Procedure Fill Nozzle Installation (TS014).
Part #
Valve A or B dispense the correct detergent into the digestion vessel. Refer to A2000 Service Procedure A and B Valve Cleaning (AS004) for instructions.
Part #
The valve opens to vent the vessel during the fill and drain processes. Refer to Service Procedure Water and Vent Valve Service (AS016) for further information.