Part #
This is the programmed touchscreen hardware used in the human interface module. This part can be purchased to replace an existing touchscreen that may be damaged in some way.
Part #
This circuit board contains the electronics that control the instrument.
Part #
The Mixer Flow Control Valve Assembly allows for better control and easier adjustment to the intensity of sample mixing to help ensure proper digestion.
Part #
The Internal Drain Hose Assembly with check valves delivers necessary chemicals for each assay. Included in the assembly are tubes that drain chemicals after their use.
Part #
This larger 4 liter chemical container is used for supplying distilled water to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.
Part #
This holder is used to position the Distilled Water, Buffer, and 78% EtOH containers in the appropriate location next to the instrument.
Part #
This 10 amp fuse is used on the DELTAI and A2000I Fiber instruments (220v) along with RD (120v) and RDI (220v). It helps protect the instrument from a possible power surge.
Part #
The ANKOM RF Maintenance Kit provides the essential tools needed to keep your RF Gas Production System operating smoothly. The following items and instructions for each are included: - (1) RF70: Positive Control Capsule Set (set includes 5 BLUE...
Part #
The Pump assembly is found in the DELTA/DELTAI Fiber instruments and includes a fill valve and pump to supply the vessel with chemicals and rinse water.
Part #
This is the High Pressure Regulator for the TDF instrument.
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground glass vessel with port and cap; used in the digestion step of the analysis. The port allows the addition of internal standards. A FLEX55 combined with a FLEX54 form a complete Digestion...
Part #
For use in the ANKOM FLEX Analyte Extractor. Precision ground round bottom flask with a 34-15 taper ground joint; used in the evaporation step of the instrument.
Part #
Power Supply A is a 10 amp transformer that supplies 24v DC power to the pump motor controller (PMC) and analog multiplexer boards MUX-T ( Part #: TDF111 ) and MUX-P ( Part #: TDF112 ). This supply is used for both 110v and 220v instruments.
Part #
These bulbs are used for heating the 120-130v DAISY instrument.
Part #
This relay replaces Part #: 6114 and controls power to the Ascon temperature controller, motor, and drain valve on the DELTA/DELTAI and A2000/A2000I Fiber instruments, as well as the HCl/HClI instrument.
Part #
This container can be used for storing solvents when not in use. When the instrument is properly configured, a cubitainer can also be used for automatically dispensing solvents during an assay. The CUBITAINER® is a disposable flexible package. It can...
Part #
This one-way valve is used for adding gas into the glass bottle of an RF1 module. This is often done to purge the bottle of existing gases. To push gas into the bottle using an Air Purge Assembly ( Part #: RF28 ), see RF Service Procedure Purge...
Part #
The Black Nitrogen Supply Tubing is used as a replacement part for cracked or damaged nitrogen supply tubing or where additional length is required. The unit price is per foot. Please specify the length in the quantity field when ordered.
Part #
This is the internal computer that controls the A2000 Fiber Analyzers.
Part #
The A10 Motor Assembly 220v drives the agitation system in the 220v DELTAI & A2000I.
Part #
Located in #FLEX30 Slide Valve and #FLEX32 Vent Valve assemblies Rev A.
Part #
Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.
Part #
This kit and the accompanying process guide provide the parts and the instructions to complete the Preventative Maintenance (PM) process for the DELTA or A2000 Automated Fiber Analyzers. This procedure should be completed annually for an instrument...
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
The Thermal Cut-off Assembly is used in the heater for the oven. It consists of a non-resettable thermal fuse that shuts down power to the heater if the temperature exceeds 240°C.
Part #
The Vent Valve Assembly functions to release pressure from the vessels during vessel fill and saponification.
Part #
This part displays the solvent level on the XT15/XT15I instruments.
Part #
Replacement silicone tubing (uncut) for all 3/16" OD tubing. Refer to TDF Service Procedure Tube Replacement (Delivery) (TS006) for installation instructions.
Part #
For use in the ANKOM FLEX Analyte Extractor. PTFE magnetic cross stir-bar; used in each assembled digestion vessel.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
The RF28 Air Purge Assembly can be used to purge the glass bottle prior to an experiment, or to pressurize the module assembly (through the Luer Duckbill Check Valve, Part #: 7139 ) to check for leaks. For module purge instructions, see RF Service...
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This cable is used to connect the Dual Lead Battery Pack ( Part #: RF46 ) to the 10-Station Battery Charger ( Part #: RF25 ). Longer extension cables are available upon request.
Part #
This switch turns power on and off to the instrument.
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
This is a replacement bottom tray for the bag suspender, which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
Replacement quick-release connector used in the top of the alcohol, buffer, and water containers, as well as in the enzyme bracket.
Part #
The pneumatically operated Pinch Valve-Waste regulates the flow of fluids to the Waste tube during line charges, flushing, and diagnostic operations. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.
Part #
This is a chemical container used for supplying HCl to the instrument.