Part #
The Mixer Piston Assembly is a pneumatic mixer which operates the paddle bar, ensuring good sample agitation during digestion.
Part #
This kit includes six replacement tubes for the peristaltic pump. Refer to TDF Service Procedure Tube Replacement (Silicone Pump Tubes) (TS003) for installation instructions.
Part #
The Flush Tubing Assembly used primarily for maintenance flushing of the fluid lines which allows the user to bypass fluid containers and connect to a single supply container.
Part #
The Agitator Apron is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It serves to funnel fluid away from the motor and into the maintenance alert assembly.
Part #
This clamp bar is used in the IDF part of the instrument to close the Filter Bag just above the filter.
Part #
Replacement silicone supply line tubing (uncut) for 1/4" OD silicone tubing. Refer to TDF Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This replacement kit includes a Fill Nozzle, retaining ring, and a spring. For replacement instructions, refer to Service Procedure Fill Nozzle Installation (TS014).
Part #
Valve A or B dispense the correct detergent into the digestion vessel. Refer to A2000 Service Procedure A and B Valve Cleaning (AS004) for instructions.
Part #
The valve opens to vent the vessel during the fill and drain processes. Refer to Service Procedure Water and Vent Valve Service (AS016) for further information.
Part #
This probe provides an accurate temperature to the Athena controller.
Part #
The Bag Suspender w/ Weight is used within the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It is the entire array that holds the filter bags in the vessel and ensures proper circulation of solutions and uniform digestion of the samples.
Part #
This switch turns the heat to the digestion vessel on and off.
Part #
The Packing Set is used in the DELTA/DELTAI, A200/A200I, and A2000/A2000I Fiber instruments. Its purpose is to create a seal and keep the solution from leaking from the vessel into the interior cabinet. This includes two lengths of graphite rope...
Part #
This assembly includes the handle and clamping device used for sealing the lid and hinge block assembly to the vessel.
Part #
This motor agitates the bag suspender at the proper RPM in the 120v instrument.
Part #
This corrosion-resistant PEEK valve body and stainless piston is the mechanical component of the Buffer supply valve as of November 2022. It is used as a replacement component for the Water, Buffer, EtOH78, and EtOH95 supply valves. It includes the...
Part #
Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.
Part #
This module cap includes a notch that allows for a battery extension cable.
Part #
This container is used to hold the Buffer for TDF CODEX methods.
Part #
The Low Pressure Sensor Assembly is used to monitor nitrogen (N2) line pressure in two locations. One marked 43 monitors N2 going to the four round bottom flasks used for solvent evaporation. One marked 45 monitors N2 Low Pressure and is displayed on...
Part #
The High Pressure Sensor Assembly is used to monitor the main nitrogen input line pressure to the instrument.
Part #
The FLEX21 Thermistor Assemblies are used to monitor temperature at eight locations. One is used to monitor the vessels' temperatures and is marked 46. One is used to monitor the reference temperature surrounding the round bottom flasks and is marked...
Part #
The RF Gen 3 Circuit Board contains the electronics used for communication with all RF1X / RF5X modules.
Part #
The RF Solenoid assembly is used to replace a faulty solenoid pinch valve within the RF1 or RF1X Module.
Part #
The FLEX Maintenance Kit provides the essential items needed to keep your FLEX Analyte Extractor operating smoohtly. The following items are included: 4 - Container Filters ( Part #: 8202 ) 4 - Vessel Top O-Ring ( Part #: 9231 ) 4 - Column top O-Ring...
Part #
This tube replacement set is used as part of preventative maintenance and includes pre-cut, bagged, and labeled lengths of silicone tubing (3/16”OD x 1/16”ID) used in the delivery of reagents in the ANKOM TDF Dietary Fiber Analyzer.
Part #
Used in older XT15/XT15I. Please contact ANKOM for more information.
Part #
The DELTA01 Maintenance Alert Assembly is used in the DELTA and A2000 instruments. It includes the Drip Tray w/plugged drain hole ( Part #: 692 ), Agitator Apron ( Part #: 638.7 ), and brass washer and functions as a collector for a fluid leak...
Part #
Pneumatic Control Solenoid Valve used in TDF and FLEX Instruments. Replacement part for a faulty Solenoid Valve.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
This holder is used to position the HCl container in the appropriate location next to the instrument.
Part #
This part protects the 220v instrument against power surges that are out-of-specification.
Part #
The Open End Wrench 1-1/8" is used to tighten the Brass Packing Nut ( Part #: 640 ) found on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments.
Part #
This is the controller with display used in the 220v RD Dryer.
Part #
The Pressure Sensor Assembly is used in the DELTA & DELTAI Fiber instruments for measuring the initial pressure before a run. It also measures the pressure during a run to monitor the process and ensure proper extraction.
Part #
The Splat Controller w/ Spice Board is used in the DELTA Fiber instrument and holds the program, controlling all funtions of the DELTA instrument.
Part #
This is the Low Pressure Regulator for the TDF instrument.
Part #
Individual replacement paddle for the ANKOM TDF paddle bar. Includes embedded temperature sensor and heater cartridge.
Part #
Used with Digestion Vessel Glass ( Part #: FLEX55 ) seal port.
Part #
Small O-ring located in Vessel Bottom Assembly ( Part #: FLEX54 ) on the bottom side.
Part #
Large O-ring located in the Vessel Bottom Assembly ( Part #: FLEX54 ) on the top, inside.
Part #
The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.
Part #
The Nitrogen Flowmeter is used to regulate nitrogen flow to FLEX instrument.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or once...
Part #
This piston is used for high-penetrating solvents and is included in the X55 Kit (XT15/XT15I) and the X73 Kit (XT10/XT10I).
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...