Part #
A 5605 Clear Glass Bottle with protective coating is one of the bottle options that can be used with an RF1 Gas Production Module or used to collect solvent vented from the XT15 and XT10 Instruments. This bottle provides the following features: - up...
Part #
This assembly heats the Extraction Chamber of the 120v HCl instrument.
Part #
The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.
Part #
Attaches on the top of the RD/RDI Dryer. This filter is used when drying filter bags after a hydrolysis operation is done with an ANKOM HCl/HCI Hydrolysis System.
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
The durable Viton™ Gasket increases the seal quality between the RF1 Gas Production Module and the glass bottle. We recommend replacing gaskets when they become worn, torn, or begin to leak. The RF34 pack includes 10 Viton™ Gaskets. For installation...
Part #
The TDF Pressure Sensor Assembly monitors the pressures of the six fluid lines and is used to identify weaknesses in tubing downstream of the peristaltic pump. Refer to TDF Service Procedure Pressure Sensor Replacement (TS011) for installation...
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
This 90° Brass Elbow is found in the DELTA/DELTAI and A2000/A2000I Fiber instruments and connects the drain valve to the exhaust hose.
Part #
The Vessel Low Pressure Sensor Assembly is used to monitor pressure in the four vessels during filling and saponification. Specify vessel 1, 2, 3 or 4 at checkout.
Part #
The Optical Bubble Sensor Assemblies function as a drain sensor and monitor fluid lines at five locations. Four sensors are used to confirm drain of the vessels. Those used for vessels 1, 2, 3, and 4 are marked 31, 32, 33,34, respectively. One marked...
Part #
Used only in the cleaning of the Vessel Tops at the end of the run for Fat analyses that use hydrochloric acid (HCl). Procedure for use is available in the FLEX Operator's Manual.
Part #
The Vessel Bottom Plug is used during the Solution Delivery Calibration of the FLEX liquid pump. It is used to seal the bottom hole of the Vessel Bottom Assembly ( Part #: FLEX54 ).
Part #
This assembly includes a probe that provides an accurate temperature to the Athena controller.
Part #
Replacement fused filter plug and on/off switch.
Part #
This assembly connects the pressure switch to the digestion vessel.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
Part #
This Extraction Vessel seal should be used when running high penetrating solvents like Diethyl Ether in your XT10/XT10I and XT15/XT15I.
Part #
The RF Gen 2 Circuit Board contains the electronics used for communication with all RF1 / RF5 modules. For installation instructions, see RF Service Procedure Chip and Board Replacement (RFS013).
Part #
The Module Cap is the red plastic part on the top of the RF1 Gas Production Module. The cap covers the electronics in the RF1 and the electronics in the RF5 Reference Module Zero.
Part #
ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7119 bottle provides the following features: - up to 100ml of space to hold analysis material - a protective coating...
Part #
This filter prevents solid material from entering the instrument through the fluid container.
Part #
If you are using cubitainers for your fiber analyses, the chemicals must move from the cubitainers to the instrument. This tubing connects a cubitainer to port A or B to deliver chemicals to the instrument.