Skip to main content

Resource Center

Displaying 1 - 50 of 116

Part #

HS

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. ​ The sealer dimensions are: 13.5"L x 4"W x 8"H

Price: $196.00
Quantity:
 

Part #

1916

Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

F08

To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.

Price: $14.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 

Part #

1917

Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

HSi

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...

Price: $196.00
Quantity:
 
 

Part #

TCH1

The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...

Price: $3,797.00
Quantity:
 

Part #

X49

This special tray system desiccator is used for high fat samples requiring weigh tins.

Price: $148.00
Quantity:
 

Part #

TCH2

The TCH2 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Chiller can support up to two extractors at the same time. • 0°...

Price: $3,797.00
Quantity:
 

Part #

6227

This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.

Price: $269.00
Quantity:
 

Part #

TP1

This ink is used by the TN2 numbering machine. It is especially useful for marking the ANKOM Filter Bags because it is chemical resistant.

Price: $26.00
Quantity:
 
 
 

Part #

A02

This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...

Price: $728.00
Quantity:
 

Part #

TP3

These un-inked pads are used in conjunction with TP1 in the TN2 marking machine.

Price: $5.00
Quantity:
 

Part #

TN2

This stamp works well for marking the F57 and F58 Filter Bags. The ink resists the chemicals and the stamp advances the number each time it is pressed down.

Price: $146.00
Quantity:
 

Part #

460

This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.

Price: $41.00
Quantity:
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

5678

The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...

Price: $115.00
Quantity:
 

Part #

X90

The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...

Price: $99.00
Quantity:
 

Part #

Z132

The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.

Price: $21.00
Quantity:
 

Part #

Z133

This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...

Price: $5.00
Quantity:
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 

Part #

461

This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.

Price: $51.00
Quantity:
 

Part #

X20

The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.

Price: $14.00
Quantity:
 

Part #

X45

The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.

Price: $11.00
Quantity:
 

Part #

Z135

The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...

Price: $5.00
Quantity:
 

Part #

X35

Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.

Price: $16.00
Quantity:
 
 

Part #

206

This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.

Price: $3.00
Quantity:
 
 
 

Part #

X96

This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.

Price: $114.00
Quantity:
 

Part #

X33

This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used...

Price: $1,148.00
Quantity:
 
 

Part #

5806

This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.

Price: $6.00
Quantity:
 

Part #

X64

The Drain Manifold Assembly is used in the XT15/XT15I Fat Extractors. It receives water from multiple cooling coils and routes it to the waste line.

Price: $165.00
Quantity:
 
 

Part #

X92

Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.

Price: $220.00
Quantity:
 
 
 

Part #

X32

This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used daily or...

Price: $332.00
Quantity:
 

Part #

963

This 120/220 volt supply provides the correct power to the instrument electronics.

Price: $196.00
Quantity:
 

Part #

X89

This is the internal computer that controls the XT15/XT15I Fat Extractor.

Price: $409.00
Quantity:
 

Part #

X83

This part is used to filter solvent vapors and should be replaced every 3 months or after 100 instrument operations. This part is only used in the XT15/XT15I instruments.

Price: $62.00
Quantity: