Skip to main content

Resource Center

Displaying 1 - 50 of 106

Part #

TDF
TDFI

Automated Dietary Fiber Analysis Automates AOAC 985.29, 991.43, and 2001.03 (AACC 32.07.01), and NMKL 129, 2003, AOAC 2009.01, 2011.25, 2017.16 and 2022.01 The ANKOM TDF Dietary Fiber Analyzer creates a new standard used for nutritional labeling...

 

Part #

DF-FT

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section when only a Total Dietary Fiber (TDF) value is required. The DF-FT bag allows the entire contents of the enzymatic digestion to Flow Thru to the lower SDF chamber...

Price: $100.00
Quantity:
 

Part #

DF-I

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the upper section to capture the Insoluble Dietary Fiber after the enzymatic digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six 50-count packs...

Price: $250.00
Quantity:
 

Part #

DF-S

For use in the ANKOM Dietary Fiber Analyzer. This bag is used in the lower section to capture and precipitate the Soluble Dietary Fiber (SDF) after the IDF digestion. Bags are sold in quantities of 50. Discounts are applied at quantities of 300 (six...

Price: $250.00
Quantity:
 

Part #

TDF31

The fluid supply distribution manifold directs input fluids to the six IDF/SDF stations. To replace the supply manifold in your instrument, follow TDF Service Procedure Supply Manifold Replacement (TS029).

Price: $252.00
Quantity:
 

Part #

TDF33

The Mixing Pad Assembly may require replacement if bent or if the pad has become loose. Refer to TDF Service Procedure Mixing Pad Adjustment (TS010) to ensure proper alignment.

Price: $61.00
Quantity:
 

Part #

TDF35

This is an enzyme container used for supplying Amylase to the instrument.

Price: $34.00
Quantity:
 

Part #

TDF52

The largest contributor to poor TDF results is the effect of static electricity on the weighing process. The TDF52 Bag Weigh Holder is used during the weighing process to eliminate static electricity while the bag is being weighed.

Price: $18.00
Quantity:
 
 

Part #

TDF69

The Vacuum Sensor Assembly monitors pressures on the supply lines and is used to identify empty containers, plugged fluid lines, or damage to a supply line. For replacement instructions, refer to Service Procedure Vacuum Sensor Installation (TS013).

Price: $157.00
Quantity:
 

Part #

TDF71

Replacement tube set for all seven pinch valves [Enzymes, IDF inlet(2), SDF Inlet(2) and Waste(2)]. Refer to Service Procedure Tube Replacement (Pinch Valves) (TS005) for installation instructions.

Price: $40.00
Quantity:
 
 
 

Part #

TDF23

The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...

Price: $2,259.00
Quantity:
 
 

Part #

TDF88

The EPDM Tubing is the replacement tube for the HCl / Acetic Acid supply lines. Refer to Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.

Price: $11.00
Quantity:
 
 

Part #

TDF117

This larger 4 liter chemical container is used for supplying buffer to the instrument. The larger size accommodates 8 runs on the instrument before refilling is necessary.

Price: $135.00
Quantity:
 

Part #

TDF111

The MUX-T board communicates temperature signals to the main controller and is critical in paddle and in-line heat control.

Price: $309.00
Quantity:
 

Part #

TDF112

The MUX-P board communicates pressure signals to the main controller and is critical in accurate pump tube test results, input pressure readings, and vacuum readings during each fluid delivery.

Price: $309.00
Quantity:
 
 

Part #

TDF65

For an existing ANKOM TDF instrument, the TDF65 Codex Method Upgrade kit will be needed to run methods AOAC 2022.01, AOAC 2017.16, AOAC 2011.25, and AOAC 2009.01. This includes: TDF17 Control Panel with Codex method software functionality TDF57...

Price: $5,500.00
Quantity:
 

Part #

TDF19

The TDF Pressure Sensor Assembly monitors the pressures of the six fluid lines and is used to identify weaknesses in tubing downstream of the peristaltic pump. Refer to TDF Service Procedure Pressure Sensor Replacement (TS011) for installation...

Price: $860.00
Quantity:
 
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 

Part #

8202

This filter prevents solid material from entering the instrument through the fluid container.

Price: $4.00
Quantity:
 

Part #

8241

The adhesive gasket is used on the rear B & D clamp bars to ensure a good seal of the IDF and SDF bags during digestions or the precipitation phase.

Price: $9.00
Quantity:
 

Part #

8194

Replacement quick-release connector insert used on the ends of the supply tubes, which connect into the top of the alcohol, buffer, and water containers. Please specify the color: Blue , Red , Green , or White .

Price: $26.00
Quantity:
 
 

Part #

TDF97

Useful in the AOAC 2009.01/2011.25 methods, this cup is used to capture the filtrate that comes through the SDF Filter Bag.

Price: $74.00
Quantity:
 

Part #

TDF120

The TDF120 In-Line heater Core is used to replace leaking brass tubing on the In-Line Heater. It includes connected silicone tubing for ease of installation. The heater cartridge and thermistor (temp sensor) are not included in this assembly.

Price: $265.00
Quantity:
 

Part #

HS

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. ​ The sealer dimensions are: 13.5"L x 4"W x 8"H

Price: $196.00
Quantity:
 

Part #

1916

Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

TDF129

The TDF129 kit provides all the tubing and parts necessary to perform the annual maintenance for a TDF instrument. This includes all the supply tubing, delivery tubing, enzyme tubing, and all related tubing plus several parts that can fatigue over...

Price: $780.00
Quantity:
 

Part #

TDF34

The nitrogen check valve prevents fluid back-up from the 12 IDF/SDF delivery lines into the pneumatic lines.

Price: $16.00
Quantity:
 
 

Part #

TDF44

This part provides for the proper flow of fluids as they enter the filter bags.

Price: $17.00
Quantity:
 

Part #

TDF50

Before the final weighing step in a Dietary Fiber analysis, the bags must be dried. The TDF50 stainless steel Bag Drying Rack has twelve positions for holding a full set of IDF/SDF bags when drying them in an oven.

Price: $109.00
Quantity:
 
 
 

Part #

8181

The TDF Torsion Bar is used in the ANKOM TDF Dietary Fiber Analyzer to provide torsion adequate to support the front safety cover of the instument.

Price: $770.00
Quantity:
 

Part #

1917

Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

HSi

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...

Price: $196.00
Quantity:
 

Part #

X45

The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.

Price: $11.00
Quantity:
 

Part #

TDF55

The pneumatically operated Enzyme Pinch Valve-N.O. regulates the input of enzymes. Refer to Service Procedure Pinch Valve Replacement (Enzymes) (TS009) for installation instructions.

Price: $540.00
Quantity:
 

Part #

8002

The Drain Tray collects waste fluids and funnels them through the Drain Tray Tube to a drain or a collection container provided by the user.

Price: $191.00
Quantity:
 

Part #

TDF98

The TDF Thermistor Assembly is used to monitor and regulate the power input to the In-line heater to maintain a steady temperature. This is important when pre-heating fluids during rinses and 95% alcohol delivery.

Price: $89.00
Quantity:
 

Part #

TDF99

The TDF99 kit is used to replace pump tubing in the ANKOM TDF instrument. The TDF99 Long-life pump tubes can only be used on instruments outfitted with pumps labeled: "HIGH TORQUE PERISTALTIC PUMP."

Price: $86.00
Quantity:
 
 

Part #

TDF29

The pneumatically operated Pinch Valve-IDF, SDF regulates the flow of fluids to the IDF and SDF positions. Refer to Service Procedure Pinch Valve Replacement (Output) (TS008) for installation instructions.

Price: $393.00
Quantity: