Skip to main content

Resource Center

Displaying 1 - 50 of 98

Part #

XT4

Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...

Price: $276.00
Quantity:
 

Part #

F57

Fiber Filter Bags 25 micron porosity- 200 Count. Order F57 Filter Bags by 200 count package quantity (e.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000...

Price: $256.00
Quantity:
 

Part #

Z132

The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.

Price: $21.00
Quantity:
 

Part #

Z133

This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...

Price: $5.00
Quantity:
 

Part #

6032

This solid state relay is used in the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, TDF/TDFI, DELTA/DELTAI, A2000/A2000I, FLEX/FLEXI. It is used to control power to the AC heaters.

Price: $137.00
Quantity:
 

Part #

Z135

The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...

Price: $5.00
Quantity:
 

Part #

HSi

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...

Price: $196.00
Quantity:
 

Part #

1917

Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

461

This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.

Price: $51.00
Quantity:
 

Part #

X20

The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.

Price: $14.00
Quantity:
 

Part #

F08

To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.

Price: $14.00
Quantity:
 

Part #

460

This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.

Price: $41.00
Quantity:
 

Part #

1918

Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 

Part #

1919

Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $30.00
Quantity:
 

Part #

5653

The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...

Price: $35.00
Quantity:
 

Part #

F58

Order F58 Filter Bags by 100 count package quantity (e.g. 10 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1000, 5000, and 10,000 quantities. The F58 filter bag is mainly designed...

Price: $157.00
Quantity:
 

Part #

X90

The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...

Price: $99.00
Quantity:
 

Part #

HS

At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. ​ The sealer dimensions are: 13.5"L x 4"W x 8"H

Price: $196.00
Quantity:
 

Part #

1916

Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.

Price: $14.00
Quantity:
 
 
 

Part #

H4

The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).

Price: $415.00
Quantity:
 
 

Part #

X49

This special tray system desiccator is used for high fat samples requiring weigh tins.

Price: $148.00
Quantity:
 
 

Part #

206

This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.

Price: $3.00
Quantity:
 

Part #

H32

This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.

Price: $153.00
Quantity:
 

Part #

H35

Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.

Price: $175.00
Quantity:
 
 
 

Part #

H38

The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.

Price: $157.00
Quantity:
 
 

Part #

H33

The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.

Price: $51.00
Quantity:
 

Part #

146.1

Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.

Price: $30.00
Quantity:
 

Part #

H2

The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. ​This assembly includes the latch that secures the lid to the instrument.

Price: $1,380.00
Quantity:
 

Part #

H3

The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.

Price: $203.00
Quantity:
 

Part #

H37

The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.

Price: $51.00
Quantity:
 

Part #

963

This 120/220 volt supply provides the correct power to the instrument electronics.

Price: $196.00
Quantity:
 

Part #

632

The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...

Price: $40.00
Quantity:
 

Part #

6227

This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.

Price: $269.00
Quantity:
 

Part #

TP1

This ink is used by the TN2 numbering machine. It is especially useful for marking the ANKOM Filter Bags because it is chemical resistant.

Price: $26.00
Quantity:
 
 
 

Part #

622

The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.

Price: $33.00
Quantity:
 

Part #

A02

This water heater, 120v can be used with the DELTA/DELTAI and A2000/A2000I Fiber instruments. It provides the required hot rinse water for DELTA/A2000 operation. If you have a 220v connection, you will need to connect this water heater to a Voltage...

Price: $728.00
Quantity:
 

Part #

A04

If you are using cubitainers for your fiber analyses, the chemicals must move from the cubitainers to the instrument. This tubing connects a cubitainer to port A or B to deliver chemicals to the instrument.

Price: $54.00
Quantity:
 
 

Part #

694

This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.

Price: $21.00
Quantity:
 

Part #

5678

The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...

Price: $115.00
Quantity:
 

Part #

703

The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.

Price: $56.00
Quantity: