Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 is a permanent ink pen made of rigid nylon. With an ultrafine tip, writing in small spaces is simple. It is used for precise labeling of various...
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used daily or...
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT15/XT15I Fat Extractor. This should be completed annually for an instrument used...
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.
Part #
Wire brush for cleaning the bottom of the XT10/XT10I and XT15/XT15I vessel. If fat residues burn to the bottom of the vessel, this tool, when used with a drill, will assist with cleaning.
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.
Part #
This kit is no longer available. However, the components of the X87 kit can be ordered individually as parts 969.5 and 5806. This O-Ring Kit includes an Extraction Vessel seal ( Part #: 969.5 ) and a Cup Insert Top seal ( Part #: 5806 ). Use this kit...
Part #
This Extraction Vessel seal should be used when running high penetrating solvents like Diethyl Ether in your XT10/XT10I and XT15/XT15I.
Part #
This O-Ring Kit includes parts that do not swell when contacting high penetrating solvents. This kit is no longer available. However, the components of the X95 kit can be ordered individually as parts #5663 and # 5806 .
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
This part is used to filter solvent vapors and should be replaced every 3 months or after 100 instrument operations. This part is only used in the XT15/XT15I instruments.
Part #
This PTFE washer is used to seal the brass solvent filter to prevent leaks in the XT10/XT10I and XT15/XT15I.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
Part #
Used in the XT15/XT15I Instrument. This kit includes replacement pistons for the four solvent valves (Q4, Q5, Q6, and Q7).
Part #
This piston is used for high-penetrating solvents and is included in the X55 Kit (XT15/XT15I) and the X73 Kit (XT10/XT10I).
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
This part displays the solvent level on the XT15/XT15I instruments.
Part #
Replacement locking Safety Valve Assembly for XT10/XT10I and XT15/XT15I. Refer to Service Procedure Valve Replacement (Safety) (XTS004) for installation instructions.
Part #
The Drain Manifold Assembly is used in the XT15/XT15I Fat Extractors. It receives water from multiple cooling coils and routes it to the waste line.
Part #
The XT Solvent Drain Valve Assembly is used in the XT15/XT15I and XT10/XT10I Fat extractors. Its function is to maintain pressure in the vessel within certain limits during the run and to drain the vessel at the end of the run.
Part #
Replacement Vent Bottle & Tube Assembly for XT15/XT15I. This includes SS tube with compression fitting, bottle cap, 500ml coated glass bottle, and 6 ft. of chemical resistant tubing.
Part #
A 5605 Clear Glass Bottle with protective coating is one of the bottle options that can be used with an RF1 Gas Production Module or used to collect solvent vented from the XT15 and XT10 Instruments. This bottle provides the following features: - up...
Part #
Used within the Extraction Vessel of the XT10/XT10I and XT15/XT15I, this assembly includes a Cup Insert and a Wave Spring Bag Holder.
Part #
This part holds the filter bags within the Cup Insert of your XT10/XT10I and XT15/XT15I.
Part #
This module is part of the level-sensing system in the XT15/XT15I. NOTE: Instruments purchased prior to 2012 may have a digital module. Contact ANKOM Technology if you need assistance to determine which module to order.
Part #
Replacement Glass Tip and Fiber Optic Cable to XT15/XT15I level sensor. Refer to Service Procedure Replace X59 Sensor & Cable with Glass Tip (X5S012) for installation instructions.
Part #
Used in older XT15/XT15I. Please contact ANKOM for more information.
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
Used in both XT10/XT10I and XT15/XT15I. The X78 Flow Control Assembly is used to visually indicate that water is flowing through the reflux circuit during the reflux cycle. Once the solvent has reached extraction temperature, the reflux circuit will...
Part #
This is the internal computer that controls the XT15/XT15I Fat Extractor.
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...