The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
Automated Total Fat Extraction The ANKOM HCl Hydrolysis System provides an easy method for performing the hydrolysis step in total fat/oil analysis . Filter Bag Technology prevents sample transfer errors and allows for batch hydrolysis of up to 15...
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HS Heat Sealer (120v 50/60HZ) is used for sealing ANKOM Filter Bags. The sealer dimensions are: 13.5"L x 4"W x 8"H
Part #
Replacement cover for the 120v and 220v Heat Sealers (Part #: HS , HSi ). This is applied over the heating element and held in place with clamp strips. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
The LCD Screen Assembly is used in the XT10 and XT15 Fat Extractors, the HCl Hydrolysis System, and the DELTA & A2000 Fiber Instruments. Mounted on the front of the instrument, this LCD screen displays temperature, time, and other functions during an...
Part #
DE1 contains 125 grams of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE1 SDS information.
Part #
The ANKOM RD Dryer 120v 50/60 HZ is designed to dry samples and resist corrosion. The following two filters can be used with the RD Dryer depending on your application: 1) The RD1 Dryer Activated Carbon Filter is used when drying filter bags before...
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
This is the internal computer that controls the HCl instrument.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
This Fat sample is to be used with our XT15/XT10/HCl instruments. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, please contact ANKOM Technology at www.ankom.com/contact/analytical-service s .
Part #
The H38 Internal Hose Replacement Kit includes all internal hoses for the HCl/HClI ANKOM Hydrolysis instruments as well as hose clamps and one 1/2" Barbed Tee fitting.
Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
This assembly heats the Extraction Chamber of the 120v HCl instrument.
Part #
The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
The ANKOM 2000 and 2000I Fiber Analyzers have been discontinued. The replacement products are the DELTA and DELTAI . ANKOM will continue to supply service and parts for the 2000 and 2000I Fiber Analyzers.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. This assembly includes the latch that secures the lid to the instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.
Part #
The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.
Part #
This 120/220 volt supply provides the correct power to the instrument electronics.
Possible Causes: (1) The dial on the heat sealer may not be turned up high enough. To seal the XT4 Bag, the dial must be set at approximately "6." (2) The heating element is broken. On the sides of the Teflon cover are two shiny metal strips that...
Part #
The Helical Coupler is used on the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It couples the agitator shaft with the motor to provide sample agitation within the vessel. For the A200/A200I instruments, refer to Service Procedure...
Part #
This transformer is used to step up or down the voltage needed for a device. Since ANKOM provides a 120v Water Heater, this transformer is needed if you have a 220v power source.
Part #
Replacement heating element for the Water Heater, 120v ( Part #: A02 ).
Part #
Replacement heating element for the A30 Water Heater, 220v (now disconnected).
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.