The ANKOM XT10 and XT10I Fat Extractors have been discontinued. The replacement products are the XT15 and XT15I . ANKOM will continue to supply service and parts for the XT10 and XT10I Fat Extractors.
Part #
To properly record results, it is best to label ANKOM Filter Bags before running an assay. The F08 Marker is an acetone resistant black marker that can be used to label ANKOM F57, F58, XT4, and In Situ Bags.
Part #
Used in both the XT10/XT10I and XT15/XT15I. This valve spring is for the Q5 solvent valve only. This spring should not be used in any other valve.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15, XT10, HCl. DELTA, and A2000.
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
This Fat sample is to be used with our XT15/XT10/HCl instruments. The purpose of the check sample is both to ensure proper function of the instrument and correct procedural technique. If your results do not meet the expected range, first check your procedural steps. If the method has been followed properly, please contact ANKOM Technology at www.ankom.com/contact/analytical-service s .
Part #
This probe is used to measure the temperature within the Extraction Vessel of an XT10/XT10I and an XT15/XT15I.
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the standard ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or once...
Part #
Replacement Insulator Strip on the 120v and 220v Heat Sealers (Part #:: HS , HSi ). This is adhesive-backed and positioned beneath the heating element. For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
Replacement Silicone Rubber Gasket for upper pressure bar (in handle) of the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
This piston is used for high-penetrating solvents and is included in the X55 Kit (XT15/XT15I) and the X73 Kit (XT10/XT10I).
Part #
The On/Off/Heat/Rotate Power Switch is used on the following ANKOM instruments: XT10/XT10I, XT15/XT15I, HCl/HClI, RD/RDI, TDF/TDFI, D200/D200I, DELTA/DELTAI, A200/A200I, A2000/A2000I, FLEX/FLEXI. On the D200/D200I Daisy Incubator, this switch also...
Part #
This cup insert top seal should be used regardless of the solvent being run in the XT10/XT10I and XT15/XT15I instruments.
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
The Bag Weigh Holder is used to hold a filter bag open for easy insertion of the sample. This part is especially useful during the weighing process.
Part #
Used within the Extraction Vessel of the XT10/XT10I and XT15/XT15I, this assembly includes a Cup Insert and a Wave Spring Bag Holder.
Part #
This is the internal computer that controls the XT10 Fat Extractor.
Part #
This kit includes replacement pistons for the two solvent valves (Q5 and Q6).
Part #
This Extraction Vessel seal should be used when running Pet Ether in your XT10/XT10I and XT15/XT15I.
Part #
This part holds the filter bags within the Cup Insert of your XT10/XT10I and XT15/XT15I.
Part #
Replacement Heating element for the 120v and 220v Heat Sealers (Part #: HS , HSi ). For an installation diagram, refer to the Heat Sealer Operation Manual.
Part #
At various times during assays involving ANKOM instruments, you will need to seal the ANKOM Filter Bags. The HSi Heat Sealer (220v 50/60HZ) is used for sealing ANKOM Filter Bags. Please specify the country where the heat sealer will be used so that...
Part #
This kit is no longer available. However, the components of the X87 kit can be ordered individually as parts 969.5 and 5806. This O-Ring Kit includes an Extraction Vessel seal ( Part #: 969.5 ) and a Cup Insert Top seal ( Part #: 5806 ). Use this kit...
Part #
This filter is used in the water supply line of the XT10/XT10I and XT15/XT15I.
Part #
The Moisture Stop Weigh Pouch contains a desiccant packet which absorbs moisture within the zipper bag. It is used when cooling and weighing filter bags to avoid unwanted absorption of moisture in the dried samples which would skew results.
Part #
This special tray system desiccator is used for high fat samples requiring weigh tins.
Part #
The Valve Spring is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and is inserted inside the Valve Piston w/ Viton® Seal. Note: For XT10/XT10I and XT15/XT15I -...
Part #
Replacement locking Safety Valve Assembly for XT10/XT10I and XT15/XT15I. Refer to Service Procedure Valve Replacement (Safety) (XTS004) for installation instructions.
Part #
The TCH2 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH2 chiller can be used with either the XT10 or XT15 extractors. One Chiller can support up to two extractors at the same time. • 0°...
Part #
Wire brush for cleaning the bottom of the XT10/XT10I and XT15/XT15I vessel. If fat residues burn to the bottom of the vessel, this tool, when used with a drill, will assist with cleaning.
Part #
Used in both XT10/XT10I and XT15/XT15I. The X78 Flow Control Assembly is used to visually indicate that water is flowing through the reflux circuit during the reflux cycle. Once the solvent has reached extraction temperature, the reflux circuit will...
Part #
This PTFE washer is used to seal the brass solvent filter to prevent leaks in the XT10/XT10I and XT15/XT15I.
Part #
The XT Solvent Drain Valve Assembly is used in the XT15/XT15I and XT10/XT10I Fat extractors. Its function is to maintain pressure in the vessel within certain limits during the run and to drain the vessel at the end of the run.
Part #
This O-Ring Kit includes parts that do not swell when contacting high penetrating solvents. This kit is no longer available. However, the components of the X95 kit can be ordered individually as parts #5663 and # 5806 .
Part #
Fat Filter Bags have 3 micron porosity. Order XT4 Filter Bags by 200 count package quantity (E.g. 5 = 1,000 filter bags). Volume discounts will be applied when added to the shopping cart. Quantity discounts apply at 1,000 and 5,000 quantities. XT4...
Part #
The valve seat is attached to the end of the valve piston within the solenoid supply valve used on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments.
Part #
This Viton™ O-ring is used within the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments for proper sealing and replaces the valve body seal O-ring around the inside of the valve guide...
Part #
This gauge shows the amount of pressure within the XT10/XT10I and XT15/XT15I Extraction Vessel during instrument operation. Operating pressure will vary depending on the solvent being used.
Part #
A 5605 Clear Glass Bottle with protective coating is one of the bottle options that can be used with an RF1 Gas Production Module or used to collect solvent vented from the XT15 and XT10 Instruments. This bottle provides the following features: - up...
Part #
Used in both the XT10/XT10I and XT15/XT15I. This metal screen filters particles and should be cleaned regularly. XT15 Service Procedure Instrument and Components Cleaning (X5S017) provides instructions for accessing this part.
Part #
This Extraction Vessel seal should be used when running high penetrating solvents like Diethyl Ether in your XT10/XT10I and XT15/XT15I.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
The TCH1 XT Chiller improves system operation and solvent recovery by maintaining optimum coolant temperature. The TCH1 chiller can be used with either the XT10 or the XT15. One Chiller can support up to two extractors at the same time. • 0° to 40°C...
Part #
This kit and the accompanying process guide provide the parts and instructions to complete the Preventative Maintenance (PM) process for the high penetration ANKOM XT10 Fat Extractor. This should be completed annually for an instrument used daily or...
Part #
This 120/220 volt supply provides the correct power to the instrument electronics.