Among other uses, acetone is used as the last rinse in a Dietary Fiber analysis. The FACE product is packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
FAD20 contains four 1 L bottles of liquid concentrate. Each bottle can be diluted with water to make 5 liters of solution. When diluted, the solution is ready for use in the Acid Detergent method. *Special handling required for International Shipment
Part #
This 10amp fuse is used in 120v AC input to the HCl, XT10, XT15, and in both TDF and TDFI on the DC output lines from the power supply. Used to protect against power surges.
Part #
ANKOM FAD20CB provides laboratories with a quick, convenient and economical way to assure consistent, high quality Acid Detergent Fiber determination results. *Special handling required for International Shipment
Part #
ANKOM FCFA20 when diluted provides 20 L of solution for part A of the Crude Fiber method. *Special handling required for International Shipment
Part #
ANKOM FCFB20 when diluted provides 20 L of solution for part B of the Crude Fiber method. *Special handling required for International Shipment
Part #
Among other uses, sulfuric acid is used in a lignin determination. FSA-72 is 72% sulfuric acid packaged in a 1 liter bottle. *Special handling is required for International Shipment
Part #
This relay monitors the heaters in the following ANKOM instruments: XT15I, XT10I, HClI, DELTAI, and A2000I.
Part #
This is the internal computer that controls the HCl instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H2 Lid/Latch Assembly seals the Extraction Chamber in the HCl instrument. This assembly includes the latch that secures the lid to the instrument.
Part #
The HCl Extraction Chamber must be sealed during an assay. The H3 lid seals the Extraction Chamber in the HCl instrument. This assembly does not include the latch that secures the lid to the instrument.
Part #
This assembly heats the Extraction Chamber of the 120v HCl instrument.
Part #
This probe is used to measure the temperature within the Extraction Chamber of the HCl instrument.
Part #
The H33 Bag Holder is used to hold the bags in the HCl Extraction Chamber during as assay. This assembly holds 20 bags. Can also be used in the RD/RDI Dryers.
Part #
This assembly heats the Extraction Chamber of the 220v HCl instrument.
Part #
Ideally, you want to remove as much acid as possible from samples before drying them. When using the blotter, you can remove a maximum amount of acid from the samples after completing the HCl extraction, and before drying in the dryer.
Part #
Connected to the vent hose, this filter is used to capture any HCl vapors.
Part #
The H37 Bag Holder is used to hold the bags in the HCl/HClI Extraction Chamber during as assay. This assembly holds 15 bags. Can also be used in the RD/RDI Dryers.
Part #
This bolt is used for securing the lid and hinge block assembly to the vessel.
Part #
The H4 valve is a replacement Water Supply Valve for the HCl/HClI. For replacement instructions, refer to Service Procedure Water Supply Valve Installation (H4) (HS003).
Part #
ANKOM Technology in-situ bags are a woven product and come in packages of 100. Some variation may take place due to handling. The R1020 Forage Bag has dimensions of 10cm x 20cm with a 50 ± 10 micron porosity.
Part #
ANKOM Technology in-situ bags are a woven product that come in packages of 100. Some variation may take place due to handling. The R510 Forage Bag has dimensions of 5cm x 10cm with a 50 ± 10 micron porosity.
Part #
Attaches on the top of the RD/RDI Dryer. This filter is used when drying filter bags before and after a fat extraction done with an ANKOM XT10/XT10I or an ANKOM XT15/XT15I Extractor.
Part #
Attaches on the top of the RD/RDI Dryer. This filter is used when drying filter bags after a hydrolysis operation is done with an ANKOM HCl/HCI Hydrolysis System.
Part #
The RF Gas Production System uses rechargeable battery packs ( #RF16/ #RF46). The RF25 10-Station Battery Charger is used to charge the RF16/RF46 Rechargeable Battery Packs. As the name says, this charger can charge 10 batteries at one time.
Part #
This resettable breaker is used to protect the instrument against power surges that are out-of-specification.
Part #
The RF28 Air Purge Assembly can be used to purge the glass bottle prior to an experiment, or to pressurize the module assembly (through the Luer Duckbill Check Valve, Part #: 7139) to check for leaks. For module purge instructions, see RF Service...
Part #
Radio frequency communication can be impacted by distance and obstructions such as metal structures. The RF29 10 ft Antennae Extension Assembly can be connected to the RF2 Base Coordinator to improve radio frequency communication by allowing the...
Part #
The pressure inside the glass bottle of the RF1 Gas Production Module is measured using a pressure sensor. The data from the sensor is then communicated through the RF2 coordinator to the GPS software using wireless technology. The RF31 Pressure...
Part #
The durable Viton™ Gasket increases the seal quality between the RF1 Gas Production Module and the glass bottle. We recommend replacing gaskets when they become worn, torn, or begin to leak. The RF34 pack includes 10 Viton™ Gaskets. For installation...
Part #
The RF Gas Production System bottles that include a septa port use a 3 mm 2-sided PTFE coated Silicone Septa to provide an easy to penetrate seal while providing minimal pressure loss per penetration. The RF35 pack includes 10 septa.
Part #
The High Pressure Sensor monitors pressure on the intake nitrogen line.
Part #
The TDF Pressure Sensor Assembly monitors the pressures of the six fluid lines and is used to identify weaknesses in tubing downstream of the peristaltic pump. Refer to TDF Service Procedure Pressure Sensor Replacement (TS011) for installation...
Part #
The pneumatically-operated Diaphragm Valve regulates the input of HCl or Acetic Acid. Refer to Service Procedure Diaphragm Valve Replacement (TS016) for installation instructions.
Part #
The Pump Assembly includes the pump head, motor, and bracket. This pump moves fluids by peristaltic action delivering fluids to the six positions.
Part #
The ETS Snap Disc Thermostat is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. It interrupts power to the heating element in an over-temperature condition.
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
The In-Line Heater Assembly is a regulated heat exchanger that pre-heats certain fluids during delivery. Refer to Service Procedure In-Line Heater Replacement (TS018) for installation instructions.
Part #
The RF22.5 Vent Valve Adapter is used to attach the 7043 Syringe to the vent valve tube to aid in cleaning the vent valve on a RF Gas Production Module. For cleaning instructions, see RF Service Procedure Vent Valve Cleaning (RFS006).
Part #
The RF41 Synthetic Grease w/PTFE is a non-toxic lubricant used to assist in creating a seal between the RF34 Viton® Gasket and the module/bottle, and between the PTFE coated septa and the septa port on the bottle. For application instructions...
Part #
The Brass Packing Nut is used in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber Instruments. When properly tightened, this ensures that the packing materials create a seal and prevent leaks from the vessel into the interior cabinet. For the A200...
Part #
This 1.8L Wide Mouth Bottle assembly attaches directly to an RF1 electrical assembly just like all of the smaller bottles. This RF1 configuration provides the largest bottle by volume and by opening available with the RF Gas Production System. If you...
Part #
This battery kit includes the following: - 1-Dual Lead RF Rechargeable Battery Pack ( Part #: RF46) - 1-5 ft Battery Extension Cable ( Part #: RF44) - 1-Red Cap with a notch for the extension cable Longer-length cables are available upon request.
Part #
This cable is used to connect the Dual Lead Battery Pack ( Part #: RF46 ) to the 10-Station Battery Charger ( Part #: RF25). Longer extension cables are available upon request.
Part #
Along with a 5 ft Extension Cable ( Part #: RF44), the Dual Lead Rechargeable Battery Pack ( Part #: RF46) provides the capability to charge your RF1 module's battery during an experiment by keeping it connected to the Battery Charger ( Part #: RF25)...
Part #
This 115v Shaker Water Bath can be used to control the temperature and mixing during an assay. A Stainless Steel Spring Tray (WB-Tray) is recommended to hold bottles in place and prevent them from toppling when the shaker bath is in operation. WB...