Instruments
Product Categories
Resources
Part #
This relay replaces Part #: 6114 and controls power to the Ascon temperature controller, motor, and drain valve on the DELTA/DELTAI and A2000/A2000I Fiber instruments, as well as the HCl/HClI instrument.
Part #
This container can be used for storing solvents when not in use. When the instrument is properly configured, a cubitainer can also be used for automatically dispensing solvents during an assay. The CUBITAINER® is a disposable flexible package. It can...
Part #
The Vessel O-Ring is used in DELTA/DELTAI and A2000/A2000I vessel lids to seal the vessel during digestion.
Part #
The Timing Belt drives the agitator in the DELTA/DELTAI and A2000/A2000I Fiber instruments.
Part #
The Glass Tip with O-ring is a part of the analog level sensing system in the DELTA/DELTAI, A2000/A2000I Fiber instruments. Found in the Fiber Optic Cable & Glass Tip assembly ( Part #: A32), it is used to detect and regulate the fill level within...
Part #
The RF Gen 2 Circuit Board contains the electronics used for communication with all RF1 / RF5 modules. For installation instructions, see RF Service Procedure Chip and Board Replacement (RFS013). OBSOLETE - NO LONGER AVAILABLE.
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The 7056 bottle provides the following features: up to 250ml of space to hold analysis material a protective coating to protect against...
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF59 bottle provides the following features: up to 1000ml of space to hold analysis material a protective coating to protect against...
Part #
The Module Cap is the red plastic part on the top of the RF1 Gas Production Module. The cap covers the electronics in the RF1 and the electronics in the RF5 Reference Module Zero.
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF56 bottle provides the following features: up to 100ml of space to hold analysis material a protective coating to protect against...
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF36 bottle provides the following features: up to 100ml of space to hold analysis material a protective coating to protect against...
Part #
LIMITED STOCK AVAILABLE. ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7127 bottle provides the following features: - up to 250ml of space to hold analysis...
Part #
LIMITED STOCK AVAILABLE. ANKOM provides many different bottles that can be connected to an RF1 Gas Production Module within the RF Gas Production System. The 7128 bottle provides the following features: - up to 500ml of space to hold analysis...
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF37 bottle provides the following features: up to 250ml of space to hold analysis material a protective coating to protect against...
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF38 bottle provides the following features: up to 500ml of space to hold analysis material a protective coating to protect against...
Part #
ANKOM provides many different bottles that can be connected to an RF Module within the RF Gas Production System. The RF39 bottle provides the following features: up to 1000ml of space to hold analysis material a protective coating to protect against...
Part #
This one-way valve is used for adding gas into the glass bottle of an RF Module. This is often done to purge the bottle of existing gases. To push gas into the bottle using an Air Purge Assembly ( Part #: RF28), see RF Service Procedure Purge Method...
Part #
Replacement quick-release connector insert used on the ends of the supply tubes, which connect into the top of the alcohol, buffer, and water containers. Please specify the color: Blue, Red, or White.
Part #
Replacement exhaust valve for A200/A200I Fiber Analyzer. For replacement instructions, refer to Service Procedure Exhaust Valve Replacement (F2.3) (FS009).
Part #
The Paddle Bar Replacement Kits includes the Paddle Bar Assembly and the tools required for its installation. The Paddle Bar functions as both a paddle mixer and heater with embedded sensors to allow for independent heat regulation at each position...
Part #
This tool is used to view the spray tips for obstructions during cleaning and maintenance.
Part #
This is a set of replacement Enzyme Tubes used in the ANKOM TDF instrument.
Part #
This is a replacement upper tray for the bag suspender which is found in the DELTA/DELTAI, A200/A200I, A2000/A2000I Fiber instruments. Eight of these are used in the bag suspender assembly.
Part #
The EPDM Tubing is the replacement tube for the HCl / Acetic Acid supply lines. Refer to Service Procedure Tube Replacement (Supply Line) (TS007) for installation instructions.
Part #
This is a maintenance tool used to clean the (6) 0.020" (0.5mm) holes in the spray tip.
Part #
Wire brush for cleaning the bottom of the XT10/XT10I and XT15/XT15I vessel. If fat residues burn to the bottom of the vessel, this tool, when used with a drill, will assist with cleaning.
Part #
Replacement locking Safety Valve Assembly for XT10/XT10I and XT15/XT15I. Refer to Service Procedure Valve Replacement (Safety) (XTS004) for installation instructions.
Part #
When unscrewed, these screws (two total - one on each side of the ANKOM TDF Dietary Fiber Analyzer) allow the instrument to tilt forward for convenient access to the back.
Part #
This module is part of the level-sensing system in the XT15/XT15I. NOTE: Instruments purchased prior to 2012 may have a digital module. Contact ANKOM Technology if you need assistance to determine which module to order.
Part #
The Drain Tray collects waste fluids and funnels them through the Drain Tray Tube to a drain or a collection container provided by the user.
Part #
The Valve Piston w/Viton® Seat is used inside the solenoid supply valves on the XT10/XT10I, XT15/XT15I, HCl/HClI, DELTA/DELTAI, A2000/A2000I, and TDF/TDFI instruments and to replace a damaged, worn, or corroded component. DELTA: found in the Vent...
Part #
The Chemical Receptacle is used to scavenge vapors to protect electrical components. For example, it can be used with NaOH (or a stronger base) when performing oxygen consumption studies. The function of the base material is to scavenge the CO2...
Part #
The RFI Filter 120v/220v is a power receptacle used on the DELTA/DELTAI, A200I, and A2000/A2000I. It is not used on the A200. It is located on the side of the instrument and connects the instrument to a power source through a removable power cord.
Part #
This 1.8L Wide Mouth Bottle is used in the RF42 assembly and is the largest bottle by volume and by opening available with the RF Gas Production System. If you have a large sample to analyze such as dough, this bottle might work best for your needs...
Part #
Used in both XT10/XT10I and XT15/XT15I. The X78 Flow Control Assembly is used to visually indicate that water is flowing through the reflux circuit during the reflux cycle. Once the solvent has reached extraction temperature, the reflux circuit will...
Part #
The glass filtrate cup is used to collect filtrate produced from the SDF bags at the end of the precipitation phase for all dietary fiber methods. This new version of the filtrate cup has a pour spout making it easier to decant for later processing...
Part #
The TDF Thermistor Assembly is used to monitor and regulate the power input to the In-line heater to maintain a steady temperature. This is important when pre-heating fluids during rinses and 95% alcohol delivery.
Part #
The TDF99 kit is used to replace pump tubing in the ANKOM TDF instrument. The TDF99 Long-life pump tubes can only be used on instruments outfitted with pumps labeled: "HIGH TORQUE PERISTALTIC PUMP."
Part #
DE2 contains 1 kg of Diatomaceous Earth, which is often used to improve the filtration process. Click the link below for the DE2 SDS information.
Part #
This is the support panel for delivery tubing that directs fluids to the six IDF or SDF positions and out to waste.
Part #
This harness provides power to, and communication from, the pressure sensors.
Part #
The TDF104 Barb Fittings are used as connectors for tubing in the ANKOM TDF instrument. This package includes 12 fittings.
Part #
These lamps light the inside of the heat and agitate switches.
Part #
The TDF105 Nylon Hex Nut pack includes 12 nuts for use in the ANKOM TDF instrument.
Part #
This quick disconnect fitting mounts onto either side of the upper enclosure of the A2000/A2000I Fiber Analyzers. The part is used to connect to the detergent solution cubitainers.
Part #
This 230v Shaker Water Bath can be used to control the temperature and mixing during an assay. A Stainless Steel Spring Tray (WB-Tray) is recommended to hold bottles in place and prevent them from toppling when the shaker bath is in operation. WB...
Part #
The TDF107 Synthetic Grease, 10 gm, is a non-toxic lubricant used to minimize friction within the peristaltic pump, thereby extending the life of peristaltic pump tubing. For application instructions, see TDF Service Procedure Long Life Pump Tube...